| DTC Code | DTC Name |
|---|---|
| P0A94-127 | DC / DC Converter Performance |
DESCRIPTION
For a description of the boost converter, Click here.
If the boost converter detects a circuit malfunction or overvoltage, it transmits this information to the MG ECU via the boost converter overvoltage signal line.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A94 | 127 | Boost converter overvoltage signal detection (overvoltage due to system malfunction) |
|
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A (all INF codes) *1 | Generator Control Module |
| P0A1B (all INF codes) *1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes) *1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes) *1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes) *1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes) *1 | Generator Phase V Current |
| P0A75 (all INF codes) *1 | Generator Phase W Current |
| P0A78-113, 128, 266, 267, 279, 284, 286, 287, 306, 806, 503, 504, 505, 506, 586, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-122, 130, 322, 324, 325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-172, 442, 547, 548, 549, 553, 554, 555, 556, 557, 585, 587, 589, 590 | DC / DC Converter Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-803 | Power Cable Malfunction |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
P0A94-127 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Remove the service plug grip. Click here
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.
Check the connection of the low voltage connector of the inverter with converter assembly.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Turn the power switch off.
Disconnect the low voltage connector from the inverter with converter assembly.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Note
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK GENERATOR RESOLVER
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| Standard resistance (Check for short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| NG |
|
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
Turn the power switch on (IG).
Disconnect the low voltage connector from the inverter with converter assembly.
Measure the voltage according to the value(s) in the table below.
| Standard voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Note
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK MOTOR RESOLVER
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| Standard resistance (Check for short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| NG |
|
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) Click here |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Remove the inverter terminal cover from the inverter with converter assembly.
For LHD vehicles, use the following procedures Click here.
For RHD vehicles, use the following procedures Click here.
Note
Lift the inverter terminal cover horizontally so that it does not tilt. Failure to do so may break the inverter cover guide pins.
| *1 | for LHD: |
| *2 | for RHD: |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
| *1 | for LHD: |
| *2 | for RHD: |
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the generator cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
| *1 | for LHD: |
| *2 | for RHD: |
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the motor cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG1)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Disconnect the generator cable and motor cable from the inverter with converter assembly.
Tech Tips
For the removal and installation procedures related to the generator cable and motor cable, (See page for LHD, Click here for RHD).
Check MG1 for an interphase short using a milliohmmeter.
| *1 | Generator Cable |
| *2 | for LHD: |
| *3 | for RHD: |
| *4 | Shielded Wire Ground |
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (° C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION) Click here |
| OK |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG2)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Disconnect the generator cable and motor cable from the inverter with converter assembly.
Tech Tips
For the removal and installation procedures related to the generator cable and motor cable, (See page for LHD, Click here for RHD).
Check MG2 for an interphase short using a milliohmmeter.
| *1 | Motor Cable |
| *2 | for LHD: |
| *3 | for RHD: |
| *4 | Shielded Wire Ground |
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (° C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION) Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Note
If the terminals connect poorly, are damaged, or contain water or foreign matter, repair or replace the wire harness or connector.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Check the connection of the motor resolver connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (HIGH VOLTAGE CONNECTOR CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Remove the connector cover from the inverter with converter assembly.
| *1 | for LHD: |
| *2 | for RHD: |
Check the connection of the high-voltage DC connector of the inverter with converter assembly.
| *1 | for LHD: |
| *2 | for RHD: |
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Check for arc marks on the terminals of the high-voltage DC connector of the inverter with converter assembly.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK SERVICE PLUG GRIP (CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.
| OK |
|---|
| Dirt or foreign objects have not entered the connection, and there is no evidence of contamination. |
| NG |
|
REPLACE SERVICE PLUG GRIP |
| OK |
|
CHECK SERVICE PLUG GRIP
| *1 | Service Plug Grip |
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE SERVICE PLUG GRIP |
| OK |
|
CHECK FRAME WIRE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
| *1 | Frame Wire (HV Battery Junction Block Side) |
Disconnect the frame wire from the HV battery junction block.
Disconnect the frame wire (high-voltage DC connector) from the inverter with converter assembly.
| *1 | for LHD: |
| *2 | for RHD: |
| *1 | Frame Wire (Inverter with Converter Assembly Side) |
| *2 | Frame Wire (HV Battery Junction Block Side) |
| *3 | Shielded Wire Ground |
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| *1 | Frame Wire (HV Battery Junction Block Side) |
| *2 | Red Mark |
| *3 | Shielded Wire Ground |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
REPLACE FRAME WIRE Click here |
| C |
|
REPLACE FRAME WIRE Click here |
| A |
|
INSPECT HV BATTERY JUNCTION BLOCK (SMRB)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Remove the HV battery junction block from the vehicle. Click here
| *1 | HV Battery Junction Block |
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE HV BATTERY JUNCTION BLOCK Click here |
| OK |
|
INSPECT HV BATTERY JUNCTION BLOCK (SMRG)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
| *1 | HV Battery Junction Block |
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| A |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| B |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| C |
|
REPLACE HV BATTERY JUNCTION BLOCK Click here |
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Note
If the terminals connect poorly, are damaged, or contain water or foreign matter, repair or replace the wire harness or connector.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY (MG ECU) - GENERATOR RESOLVER)
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
| Standard resistance (Check for short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Tech Tips
The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Note
If the terminals connect poorly, are damaged, or contain water or foreign matter, repair or replace the wire harness or connector.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY (MG ECU) - MOTOR RESOLVER)
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
| Standard resistance (Check for short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Tech Tips
The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
Remove the hybrid vehicle transmission assembly Click here.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the generator cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK GENERATOR CABLE
Remove the generator cable from the hybrid vehicle transmission assembly. Click here
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| *1 | Generator Cable |
| *2 | for LHD: |
| *3 | for RHD: |
| *4 | Shielded Wire Ground |
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here |
| NG |
|
REPLACE GENERATOR CABLE Click here |
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
Remove the hybrid vehicle transmission assembly. Click here
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the motor cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK MOTOR CABLE
Remove the motor cable from the hybrid vehicle transmission assembly. Click here
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| *1 | Motor Cable |
| *2 | for LHD: |
| *3 | for RHD: |
| *4 | Shielded Wire Ground |
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here |
| NG |
|
REPLACE MOTOR CABLE Click here |