POWER SWITCH INSPECTION

PROCEDURE


  1. INSPECT POWER SWITCH


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      7 (SS1) - 5 (GND) Not pushed 10 kΩ or higher
      2 (SS2) - 5 (GND) Not pushed 10 kΩ or higher
      7 (SS1) - 5 (GND) Pushed Below 1 Ω
      2 (SS2) - 5 (GND) Pushed Below 1 Ω
      A000ZORE03
      Component without harness connected
      *1 (Power Switch)
      *2 No Pin

      If the result is not as specified, replace the power switch.

    2. Apply battery voltage between the terminals of the switch, and check the illumination condition of the switch.

      Tech Tips


      • If the positive (+) lead and the negative (-) lead are incorrectly connected, the power switch indicator will not illuminate.


      • If the voltage is too low, the indicator will not illuminate.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 11 (SWIL)

      Battery negative (-) → Terminal 4 (COM) or 5 (GND)

      Illuminates (illumination of lettering)

      Battery positive (+) → Terminal 12 (INDS)

      Battery negative (-) → Terminal 4 (COM) or 5 (GND)

      Illuminates (green)

      Battery positive (+) → Terminal 13 (INDW)

      Battery negative (-) → Terminal 4 (COM) or 5 (GND)

      Illuminates (amber)
      A000WMJE03
      *1 Component without harness connected: (Power Switch)
      *2 No Pin

      If the result is not as specified, replace the power switch.