OIL LEVEL SENSOR INSPECTION

PROCEDURE


  1. INSPECT ENGINE OIL LEVEL SENSOR


    1. A000ULZE02

      Partially immerse the sensor in an oil bath and warm up the oil bath.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 ON, 20°C (68°F) Below 1 Ω
      OFF, 20°C (68°F) Below 1 Ω
      ON, 60°C (140°F) Below 1 Ω
      OFF, 60°C (140°F) 10 kΩ or higher

      If the result is not as specified, replace the sensor.