FUEL RELIEF VALVE INSPECTION

PROCEDURE


  1. INSPECT FUEL RELIEF VALVE ASSEMBLY


    1. A000XBVE04

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 (CCV) - 2 (+B) 20°C (68°F) 2.0 to 2.4 Ω

      If the result is not as specified assembly, replace the fuel relief valve assembly.