AIR CLEANER AND HOSE INSTALLATION

PROCEDURE


  1. INSTALL AIR CLEANER ASSEMBLY LH


    1. A000UF7E05
      *1 Boss

      Align the air cleaner cases 2 holes to the 2 stud bolts and attach the air cleaner case LH to the boss. Then install the 2 nuts.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    2. Install the air cleaner filter element to the air cleaner case LH.

    3. A000ZO1

      Install the air cleaner cap LH and secure the 2 clamps.

    4. Connect the mass air flow meter connector.

  2. INSTALL AIR CLEANER ASSEMBLY RH


    1. A000Y9NE04
      *1 Boss

      Align the air cleaner cases 2 holes to the 2 stud bolts and attach the air cleaner case RH to the boss. Then install the 2 nuts.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    2. Install the air cleaner filter element to the air cleaner case RH.

    3. A000UQ4

      Install the air cleaner cap RH and secure the 2 clamps.

    4. Connect the mass air flow meter connector.

  3. INSTALL INTAKE AIR CONNECTOR PIPE

    Click here

  4. INSTALL NO. 1 AIR CLEANER INLET

    Click here

  5. INSTALL AIR CLEANER INLET COVER SUB-ASSEMBLY

    Click here

  6. INSTALL V-BANK COVER SUB-ASSEMBLY

    Click here