CIRCUIT OPENING RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT CIRCUIT OPENING RELAY (C/OPN)

    A000UYVE02

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 When no battery voltage is applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the circuit opening relay.