HYBRID BATTERY CONTROL SERVICE DATA

SMRB (HV battery junction block assembly)

Resistance

g2-1 (CBI) - z30-1 (+)

10 kΩ or higher

(Battery voltage is not applied between terminals z38-3 [SMRB] and z38-2 [GND])

g2-1 (CBI) - z30-1 (+)

Below 1Ω

(Battery voltage is applied between terminals z38-3 [SMRB] and z38-2 [GND])

g2-1 (CBI) - z58-1 (CBD)

Below 1Ω

(Always)

g2-1 (CBI) - z27-1 (CBPE)

Below 1Ω

(Always)

z38-3 (SMRB) - z38-2 (GND) 18.8 to 32.1 Ω at -35 to 80°C (-31 to 176°F)

SMRG (HV battery junction block assembly)

Resistance

g3-1 (CEI) - z34-1 (-)

10 kΩ or higher

(Battery voltage is not applied between terminals z38-1 [SMRG] and z38-2 [GND])

g3-1 (CEI) - z34-1 (-)

Below 1Ω

(Battery voltage is applied between terminals z38-1 [SMRG] and z38-2 [GND])

g3-1 (CEI) - z59-1 (CED)

Below 1Ω

(Always)

z34-1 (-) - z60-1 (INR)

Below 1Ω

(Always)

g3-1 (CEI) - z27-4 (CEPE)

Below 1Ω

(Always)

z38-1 (SMRG) - z38-2 (GND) 18.8 to 32.1 Ω at -35 to 80°C (-31 to 176°F)

luggage room junction block (Battery blower relay)

Resistance (BATT FAN1)

LG-1 - LD-3

10 kΩ or higher

(Battery voltage is not applied between terminals LH-1 and LD-14)

LG-1 - LD-3

Below 1Ω

(Battery voltage is applied between terminals LH-1 and LD-14)

luggage room junction block (Battery blower relay)

Resistance (BATT FAN2)

LG-1 - LA-41

10 kΩ or higher

(Battery voltage is not applied between terminals LH-1 and LD-14)

LG-1 - LA-41

Below 1Ω

(Battery voltage is applied between terminals LH-1 and LD-14)