REAR EVAPORATOR TEMPERATURE SENSOR(w/o Rear Air Conditioning System) INSPECTION

PROCEDURE


  1. INSPECT REAR EVAPORATOR TEMPERATURE SENSOR

    A000XFAE01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      7 (-) - 8 (+) -10°C (14°F) 7.30 to 9.10 kΩ
      -5°C (23°F) 5.65 to 6.95 kΩ
      0°C (32°F) 4.40 to 5.35 kΩ
      5°C (41°F) 3.40 to 4.15 kΩ
      10°C (50°F) 2.70 to 3.25 kΩ
      15°C (59°F) 2.14 to 2.58 kΩ
      20°C (68°F) 1.71 to 2.05 kΩ
      25°C (77°F) 1.38 to 1.64 kΩ
      30°C (86°F) 1.11 to 1.32 kΩ

      If the result is not as specified, replace the rear evaporator temperature sensor.

      Note


      • Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Tech Tips

      As the temperature increases, the resistance decreases (see the graph).

      Text in Illustration
      *a

      Component without harness connected

      (Rear Evaporator Temperature Sensor)

      *b Sensing Portion
      *c Resistance (kΩ)
      *d Allowable Range
      *e Temperature °C (°F)