ACTUATOR CHECK
Turn the power switch ON (IG) while pressing the A/C control AUTO switch and Recirculation / Fresh switch simultaneously.
Press the Recirculation / Fresh switch.
As each damper, motor and relay automatically operate the actuator check at 1 second intervals from step No. 1 to No. 10 continuously, check the temperature and airflow visually and by hand.
Tech Tips
If a slower display is desired, press the driver temperature up switch and change the display in the step operation. Each time the driver temperature up switch is pressed, the display changes by 1 step.
The buzzer sounds when the displayed trouble code changes.
Codes are displayed from smaller to larger numbers in order.
To cancel the check mode, press the "OFF" switch.
| Step No. | Display Code | Conditions | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Blower Level | Air Mix Damper HOT Dr. Pa. |
Air Mix Damper COOL Dr. Pa. |
Air Mix Damper FrRr Dr. Pa. |
Airflow Vent Dr. Pa. |
Airflow Vent FrRr |
M/H Bypass Damper | Air Inlet Damper | Cool Air Bypass Damper Dr. Pa. |
Compressor | ||
| 1 | 0 | 0 | 0% open | 0% open | 0% open | FACE | FACE | M/C | FRESH | -14% | OFF |
| 2 | 1 | 1 | 0% open | 0% open | 0% open | FACE | FACE | M/C | FRESH | -14% | OFF |
| 3 | 2 | 17 | 0% open | 0% open | 0% open | FACE | FACE | M/C | RECIRCULATION / FRESH | -14% | ON |
| 4 | 3 | 17 | 0% open | 0% open | 0% open | FACE | FACE | M/C | RECIRCULATION | 113.5% | ON |
| 5 | 4 | 17 | 50% open | 50% open | 50% open | B/L | B/L | Temperature Control | RECIRCULATION | 113.5% | ON |
| 6 | 5 | 17 | 50% open | 50% open | 50% open | B/L | B/L | Temperature Control | RECIRCULATION | 113.5% | ON |
| 7 | 6 | 17 | 50% open | 50% open | 50% open | FOOT | FOOT | Temperature Control | FRESH | 113.5% | ON |
| 8 | 7 | 17 | 100% open | 100% open | 100% open | FOOT-0 | FOOT | M/H | FRESH | 113.5% | ON |
| 9 | 8 | 17 | 100% open | 100% open | 100% open | F/D | FOOT | M/H | FRESH | 113.5% | ON |
| 10 | 9 | 31 | 100% open | 100% open | 100% open | DEF | FOOT | DEF | FRESH | 113.5% | ON |
| Step No. | Display Code | Conditions | |||||
|---|---|---|---|---|---|---|---|
| Rear Blower Level | Rear Airflow Vent* Dr. Pa. |
Rear Emission* | Rear Diffusion* | Rear Magnetic Valve* | HV Battery Cool Down | ||
| 1 | 0 | 0 | FACE | Close | Close | OFF | Cabin Air Inlet |
| 2 | 1 | 3 | FACE | Close | Close | OFF | Cabin Air Inlet |
| 3 | 2 | 17 | FACE | Close | Close | OFF | Cabin Air Inlet |
| 4 | 3 | 17 | FACE | Close | Close | OFF | Cabin Air Inlet |
| 5 | 4 | 17 | B/L | Close | Open | OFF | Cabin Air Inlet |
| 6 | 5 | 17 | B/L | Close | Open | ON | Rear Cooler Air Inlet |
| 7 | 6 | 17 | FOOT | Open | Close | ON | Rear Cooler Air Inlet |
| 8 | 7 | 17 | FOOT | Open | Close | ON | Rear Cooler Air Inlet |
| 9 | 8 | 17 | FOOT | Open | Close | ON | Rear Cooler Air Inlet |
| 10 | 9 | 31 | FOOT | Open | Close | ON | Rear Cooler Air Inlet |
*: w/ Rear Cooler