AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST

Tech Tips

Using the GTS to read the Data List allows values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

Note

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


  1. DATA LIST


    1. Connect the GTS to the DLC3.

    2. Turn the power switch ON (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / (desired menu) / Data List.

    5. According to the display on the GTS, read the "Data List".

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor

      Room temperature sensor /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual room temperature for front seat is displayed

      Open in circuit: -6.5°C (20.3°F)

      Short in circuit: 57.25°C (135.05°F)

      Ambient Temp Sensor

      Ambient temperature sensor /

      Min.: -23.3°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature is displayed

      Open in circuit: -23.3°C (-9.94°F)

      Short in circuit: 65.95°C (150.71°F)

      Evaporator Fin Thermistor

      Evaporator fin thermistor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature is displayed

      Open in circuit: -29.7°C (-21.46°F)

      Short in circuit: 59.55°C (139.19°F)

      Evaporator Target Temp

      Target evaporator temperature /

      Min.: -327.68°C (-557.8°F)

      Max.: 327.67°C (621.8°F)

      Target evaporator temperature is displayed -
      Solar Sensor (D Side)

      Driver side automatic light control sensor /

      Min.: 0, Max.: 255

      Driver side automatic light control sensor value increases as brightness increases -
      Solar Sensor (P Side)

      Front passenger side automatic light control sensor /

      Min.: 0, Max.: 255

      Front passenger side automatic light control sensor value increases as brightness increases -
      Engine Coolant Temp

      Engine coolant temperature /

      Min.: 1.3°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature is displayed while engine is warmed up -
      Duct Sensor (D Side)

      Duct sensor (for driver side) /

      Min.: -12.7°C (9.14°F)

      Max.: 76.55°C (169.79°F)

      Actual duct temperature is displayed (for driver side) -
      Duct Sensor (P Side)

      Duct sensor (for passenger side) /

      Min.: -12.7°C (9.14°F)

      Max.: 76.55°C (169.79°F)

      Actual duct temperature is displayed (for passenger side) -
      Set Temperature (D Side) Driver side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT Driver side actual set temperature is displayed

      18 to 32°C (0.5°C increments)

      (64.4 to 89.6 °F [0.9°F increments])

      Set Temperature (P Side) Passenger side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT Passenger side actual set temperature is displayed

      18 to 32°C (0.5°C increments)

      (64.4 to 89.6 °F [0.9°F increments])

      Hand Free Telephone Handsfree telephone / OFF or ON

      ON: Handsfree telephone is used

      OFF: Handsfree telephone is not used

      -
      Blower Motor Speed Level

      Blower motor speed level /

      Min.: 0 level

      Max.: 31 level

      Increases in range between 0 and 31 as blower motor speed increases -
      Adjusted Ambient Temp

      Adjusted ambient temperature /

      Min.: -30.8°C (-23.44°F)

      Max.: 50.8°C (123.44°F)

      Adjusted ambient temperature is displayed -
      Emission Gas Sensor

      Emission gas sensor /

      Min.: 0, Max.: 255

      Increases as the gas amount increases -
      Air Inlet Damper Targ Pulse

      Air inlet damper target pulse /

      for LHD Min.: 8, Max.: 31

      for RHD Min.: 7, Max.: 30

      for LHD:


      • RECIRCULATION: 8 (pulse)

      • FRESH: 31 (pulse)

      for RHD:


      • RECIRCULATION: 30 (pulse)

      • FRESH: 7 (pulse)

      -
      Cool Air Bypass Pulse

      Driver side cool air bypass servo motor target pulse /

      for LHD Min.: 19, Max.: 116

      for RHD Min.: 6, Max.: 103

      for LHD:


      • Shut: 19 (pulse)

      • Open: 116 (pulse)

      for RHD:


      • Shut: 103 (pulse)

      • Open: 6 (pulse)

      -
      Compressor Speed

      Compressor speed /

      Min.: 0, Max.: 65535 rpm

      Actual compressor speed is displayed -
      Compressor Target Speed

      Compressor target speed /

      Min.: 0, Max.: 65535 rpm

      Compressor target speed is displayed -
      Rear Solar Sensor

      Rear solar sensor /

      Min.: 0, Max.: 255

      Rear solar sensor value increases as brightness increases -
      Emission Gas Nox Sensor

      Emission gas NOx sensor /

      Min.: 0, Max.: 255

      Increases as gas amount increases -
      Regulator Pressure Sensor

      Refrigerant pressure sensor /

      Min.: -0.4566 MPaG

      Max.: 3.2943 MPaG

      Actual refrigerant pressure is displayed -
      Room Temp Sensor (Rear)

      Rear room temperature sensor (for LH seat) /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual rear room temperature for LH seat is displayed

      Open circuit: -6.5°C (20.3°F)

      Short circuit: 57.25°C (135.05°F)

      Ambient Temp Sens (Rear)

      Rear evaporator temperature sensor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual rear evaporator temperature is displayed

      Open in circuit: -29.7°C (-21.46°F)

      Short in circuit: 59.55°C (139.19°F)

      Blower Motor Level (Rear)

      Rear blower motor speed level /

      Min.: 0, Max.: 31

      Increases in range between 0 to 31 as rear blower motor speed increases -
      Humidity Sensor

      Humidity Sensor /

      Min.: 0%, Max.: 100%

      Actual room humidity is displayed -
      HOT A/M Servo Targ Pls(D)

      Driver side HOT air mix servo motor target pulse /

      Min.: 87, Max.: 191

      MAX HOT: 87 (pulse)

      MIN HOT: 191 (pulse)

      -
      COOL A/M Servo Targ Pls(D)

      Driver side COOL air mix servo motor target pulse /

      Min.: 90, Max.: 194

      MAX COOL: 194 (pulse)

      MIN COOL: 90 (pulse)

      -
      HOT A/M Servo Targ Pls(P)

      Passenger side HOT air mix servo motor target pulse /

      Min.: 87, Max.: 191

      MAX HOT: 87 (pulse)

      MIN HOT: 191 (pulse)

      -
      COOL A/M Servo Targ Pls(P)

      Passenger side COOL air mix servo motor target pulse /

      Min.: 90, Max.: 194

      MAX COOL: 194 (pulse)

      MIN COOL: 90 (pulse)

      -
      A/O Damper FACE Pos(D)

      Driver side FACE air outlet servo motor target pulse /

      for LHD Min.: 7, Max.: 126

      for RHD Min.: 32, Max.: 151

      for LHD:


      • Shut: 7 (pulse)

      • Open: 126 (pulse)

      for RHD:


      • Shut: 151 (pulse)

      • Open: 32 (pulse)

      -
      A/O Damper FOOT/DEF Pos(D)

      Driver side FOOT/DEF air outlet servo motor target pulse /

      for LHD Min.: 86, Max.: 156

      for RHD Min.: 26, Max.: 96

      for LHD:


      • FACE: 146 to 156 (pulse)

      • B/L 1&2: 138 (pulse)

      • FOOT: 113 to 138 (pulse)

      • FOOT/DEF: 96 (pulse)

      • DEF: 86 (pulse)

      for RHD:


      • FACE: 26 to 36 (pulse)

      • B/L 1&2: 44 (pulse)

      • FOOT: 44 to 69 (pulse)

      • FOOT/DEF: 86 (pulse)

      • DEF: 96 (pulse)

      -
      A/O Damper FACE Pos(P)

      Passenger side FACE air outlet servo motor target pulse /

      for LHD Min.: 32, Max.: 151

      for RHD Min.: 7, Max.: 126

      for LHD:


      • Shut: 151 (pulse)

      • Open: 32 (pulse)

      for RHD:


      • Shut: 7 (pulse)

      • Open: 126 (pulse)

      -
      A/O Damper FOOT/DEF Pos(P)

      Passenger side FOOT/DEF air outlet servo motor target pulse /

      for LHD Min.: 26, Max.: 96

      for RHD Min.: 86, Max.: 156

      for LHD:


      • FACE: 26 to 36 (pulse)

      • B/L 1&2: 44 (pulse)

      • FOOT: 44 to 69 (pulse)

      • FOOT/DEF: 86 (pulse)

      • DEF: 96 (pulse)

      for RHD:


      • FACE: 146 to 156 (pulse)

      • B/L 1&2: 138 (pulse)

      • FOOT: 113 to 138 (pulse)

      • FOOT/DEF: 96 (pulse)

      • DEF: 86 (pulse)

      -
      M/H Bypass HOT Targ Pls

      Max hot bypass servo motor HOT target pulse /

      Min.: 18, Max.: 168

      Shut: 18 (pulse)

      Open: 168 (pulse)

      -
      M/H Bypass COOL Targ Pls

      Max hot bypass servo motor COOL target pulse /

      for LHD Min.: 51, Max.: 63

      for RHD Min.: 67, Max.: 78

      for LHD:


      • Shut: 63 (pulse)

      • Open: 51 (pulse)

      for RHD:


      • Shut: 67 (pulse)

      • Open: 78 (pulse)

      -
      Air Mix Servo Targ Pls(F&R D)

      Driver side front A/C rear air flow air mix servo motor target pulse /

      for LHD Min.: 18, Max.: 103

      for RHD Min.: 43, Max.: 128

      for LHD:


      • MAX COOL: 18 (pulse)

      • MAX HOT: 103 (pulse)

      for RHD:


      • MAX COOL: 128 (pulse)

      • MAX HOT: 43 (pulse)

      -
      Air Mix Servo Targ Pls(F&R P)

      Passenger side front A/C rear air flow air mix servo motor target pulse /

      for LHD Min.: 43, Max.: 128

      for RHD Min.: 18, Max.: 103

      for LHD:


      • MAX COOL: 128 (pulse)

      • MAX HOT: 43 (pulse)

      for RHD:


      • MAX COOL: 18 (pulse)

      • MAX HOT: 103 (pulse)

      -
      Air Outlet Servo Pls (F&R D)

      Driver side front A/C rear air flow air outlet target pulse /

      for LHD Min.: 20, Max.: 119

      for RHD Min.: 43, Max.: 142

      for LHD:


      • RrFOOT: 20 (pulse)

      • RrB/L: 42 (pulse)

      • RrFACE: 119 (pulse)

      for RHD:


      • RrFOOT: 142 (pulse)

      • RrB/L: 120 (pulse)

      • RrFACE: 43 (pulse)

      -
      Air Outlet Servo Pls (F&R P)

      Passenger side front A/C rear air flow air outlet target pulse /

      for LHD Min.: 43, Max.: 142

      for RHD Min.: 20, Max.: 119

      for LHD:


      • RrFOOT: 142 (pulse)

      • RrB/L: 120 (pulse)

      • RrFACE: 43 (pulse)

      for RHD:


      • RrFOOT: 20 (pulse)

      • RrB/L: 42 (pulse)

      • RrFACE: 119 (pulse)

      -
      Air Outlet Servo Pulse (R)

      Rear air outlet servo motor target pulse (for LH side)/

      Min.: 8, Max.: 37

      Rear cooler ON: 37 (pulse)

      Air purifier ON: 8 (pulse)

      -
      Air Outlet Servo Pulse (RP)

      Rear air outlet servo motor target pulse (for RH side)/

      Min.: 8, Max.: 37

      Rear cooler ON: 37 (pulse)

      Air purifier ON: 8 (pulse)

      -
      COOL Bypass Target Pulse (P)

      Passenger side COOL air bypass servo motor target pulse /

      for LHD Min.: 6, Max.: 103

      for RHD Min.: 19, Max.: 116

      for LHD:


      • Shut: 6 (pulse)

      • Open: 103 (pulse)

      for RHD:


      • Shut: 116 (pulse)

      • Open: 19 (pulse)

      -
      Emission Target Pulse (R)

      Rear exhaust mode servo motor target pulse (for emission) /

      Min.: 8, Max.: 37

      Emission mode: 37 (pulse) -
      Diffuse Target Pulse (R)

      Rear exhaust mode servo motor target pulse (for diffusion) /

      Min.: 8, Max.: 46

      Diffusion mode: 46 (pulse) -
      Room Temperature Sensor (RP)

      Rear room temperature sensor (for RH seat) /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual rear room temperature for RH seat is displayed

      Open circuit: -6.5°C (20.3°F)

      Short circuit: 57.25°C (135.05°F)

      Set Temperature (Rear D side) Rear driver side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT Rear driver side actual set temperature is displayed

      18 to 32°C (0.5°C increments)

      (64.4 to 89.6 °F [0.9°F increments])

      Set Temperature (Rear P side) Rear passenger side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT Rear passenger side actual set temperature is displayed

      18 to 32°C (0.5°C increments)

      (64.4 to 89.6 °F [0.9°F increments])

      Estimated Temp (Rear D side)

      Rear driver side estimated temperature /

      Min.: -358.4°C (-613.12°F)

      Max.: 358.4°C (677.12°F)

      Rear driver side estimated temperature displayed -
      Estimated Temp (Rear P side)

      Rear passenger side estimated temperature /

      Min.: -358.4°C (-613.12°F)

      Max.: 358.4°C (677.12°F)

      Rear passenger side estimated temperature displayed -
      Add Foot Air in FACE Mode Add foot air in face mode / ON, OFF Customized value will be displayed -
      ECO MODE Cancel ECO MODE Cancel / ON, OFF Customized value will be displayed -
      Shift Set Temperature Shift set temperature / 2C incr, 1C incr, Normal, 1C decr, 2C decr Customized value will be displayed -
      Air Inlet Mode Air inlet mode / Auto, Manual Customized value will be displayed -
      Compressor Mode Compressor mode / Auto, Manual Customized value will be displayed -
      Emission Gas Sensor Shift Emission gas sensor shift / Mu More, More, Li More, Normal, Li Less, Less, Mu Less Customized value will be displayed -
      Button Press Buzzer Button press buzzer / ON, OFF Customized value will be displayed -
      Foot/DEF Auto Mode FOOT/DEF auto mode / ON, OFF Customized value will be displayed -
      Foot/DEF Auto Blow Up FOOT/DEF auto blower up function / ON, OFF Customized value will be displayed -
      Filter Sensor Filter sensor / Less, Normal, More Customized value will be displayed -
      Rear A/P HI Set Rear A/P HI Set auto mode / ON, OFF Customized value will be displayed -
      Ambient Temperature Shift Ambient temperature shift / 3C incr, 2C incr, 1C incr, Normal, 1C decr, 2C decr, 3C decr Customized value will be displayed -
      Batt Cool Down Servo Targ Pls

      HV battery cool down servo motor target pulse/

      Min.: 8, Max.: 30

      A/C intake air position: 8

      Interior intake air position: 30

      -
      Infrared Rays Sensor 1

      Infrared ray sensor 1

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Infrared Rays Sensor 2

      Infrared ray sensor 2

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Infrared Rays Sensor 3

      Infrared ray sensor 3

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Infrared Rays Sensor 4

      Infrared ray sensor 4

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Infrared Rays Sensor 5

      Infrared ray sensor 5

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Infrared Rays Sensor 6

      Infrared ray sensor 6

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Infrared Rays Sensor 7

      Infrared ray sensor 7

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Infrared Rays Sensor 8

      Infrared ray sensor 8

      Min.: 1°C (33.8°F)

      Max.: 50.5°C (122.9°F)

      Actual human body temperature is displayed

      Open in circuit: 1°C (33.8°F)

      Short in circuit: 50.5°C (122.9°F)

      Humidity Level

      Status of humidity sensor /

      Normal humidity, Low humidity

      Actual humidity status is displayed -
      Number of Trouble Codes

      Number of trouble codes /

      Min.: 0, Max.: 255

      Number of DTCs will be displayed -
  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Test.


    1. Connect the GTS to the DLC3.

    2. Turn the power switch ON (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. According to the display on the GTS, perform the "Active Test".

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower motor Min.: 0, Max.: 31 -
      Compressor Target Speed Compressor target speed Min.: 0, Max.: 65535 rpm -
      Defogger Relay (Rear) Defogger relay (Rear) OFF or ON -
      Deicer Relay (Front) Deicer relay (Front) OFF or ON -
      Mirror Heater Relay Mirror heater relay OFF or ON -
      Rear A/C Mag Valve Rear A/C magnetic valve OFF or ON -
      Water Pump Water pump relay OFF or ON -
      Electrical Fan Electrical fan OFF or ON -
      Heater Active Level Heater active level Min.: 0, Max.: 3 -
      Air Inlet Damper Targ Pulse Air inlet damper target pulse

      for LHD Min.: 8, Max.: 31

      for RHD Min.: 7, Max.: 30

      -
      Cool Air Bypass Pulse Driver side cool air bypass pulse Min.: 19, Max.: 116 -
      Hot A/M Servo Pulse(D) HOT Air mix servo motor pulse (Driver side) Min.: 87, Max.: 191 -
      Cool A/M Servo Pulse(D) COOL Air mix servo motor pulse (Driver side) Min.: 90, Max.: 194 -
      Hot A/M Servo Pulse(P) HOT Air mix servo motor pulse (Passenger side) Min.: 87, Max.: 191 -
      Cool A/M Servo Pulse(P) COOL Air mix servo motor pulse (Passenger side) Min.: 90, Max.: 194 -
      Face A/O Servo Pulse(D) FACE Air outlet servo motor pulse (Driver side)

      for LHD Min.: 7, Max.: 126

      for RHD Min.: 32, Max.: 151

      -
      Foot A/O Servo Pulse(D) FOOT Air outlet servo motor pulse (Driver side)

      for LHD Min.: 86, Max.: 156

      for RHD Min.: 26, Max.: 96

      -
      Face A/O Servo Pulse(P) FACE Air outlet servo motor pulse (Passenger side)

      for LHD Min.: 32, Max.: 151

      for RHD Min.: 7, Max.: 126

      -
      Foot A/O Servo Pulse(P) FOOT Air outlet servo motor pulse (Passenger side)

      for LHD Min.: 26, Max.: 96

      for RHD Min.: 86, Max.: 156

      -
      M/H Bypass Hot Servo Pls M/H bypass HOT servo motor pulse Min.: 18, Max.: 168 -
      M/H Bypass Cool Servo Pls M/H bypass COOL servo motor pulse

      for LHD Min.: 51, Max.: 63

      for RHD Min.: 67, Max.: 78

      -
      A/M Servo Pulse(F&R D) Air mix servo motor pulse (Front A/C rear air flow driver side)

      for LHD Min.: 18, Max.: 103

      for RHD Min.: 43, Max.: 128

      -
      A/M Servo Pulse(F&R P) Air mix servo motor pulse (Front A/C rear air flow passenger side)

      for LHD Min.: 43, Max.: 128

      for RHD Min.: 18, Max.: 103

      -
      A/O Servo Pulse(F&R D) Air outlet servo motor pulse (Front A/C rear air flow driver side)

      for LHD Min.: 20, Max.: 119

      for RHD Min.: 43, Max.: 142

      -
      A/O Servo Pulse(F&R P) Air outlet servo motor pulse (Front A/C rear air flow passenger side)

      for LHD Min.: 43, Max.: 142

      for RHD Min.: 20, Max.: 119

      -
      A/O Servo Pulse(Rr D) Air outlet servo motor pulse (Rear driver side)

      for LHD Min.: 6, Max.: 28

      for RHD Min.: 14, Max.: 36

      -
      A/O Servo Pulse(Rr P) Air outlet servo motor pulse (Rear passenger side)

      for LHD Min.: 14, Max.: 36

      for RHD Min.: 6, Max.: 28

      -
      Cool Air Bypass Pls(P) Cool air bypass pulse (Passenger side)

      for LHD Min.: 6, Max.: 103

      for RHD Min.: 19, Max.: 116

      -
      Emission Pulse(R) Emission pulse (Rear) Min.: 8, Max.: 37 -
      Diffuse Pulse(R) Diffuse pulse (Rear) Min.: 8, Max.: 46 -
      Batt Cool Down Servo Targ Pls HV battery cool down servo motor target pulse Min.: 8, Max.: 30 -
      Rear Blower Motor Rear blower motor Min.: 0, Max.: 31 -
      Ion Generator Ion generator OFF or ON -