Tech Tips
Using the GTS to read the Data List allows values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
DATA LIST
Connect the GTS to the DLC3.
Turn the power switch ON (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / (desired menu) / Data List.
According to the display on the GTS, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual room temperature for front seat is displayed | Open in circuit: -6.5°C (20.3°F) Short in circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature is displayed | Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F) |
| Evaporator Fin Thermistor | Evaporator fin thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature is displayed | Open in circuit: -29.7°C (-21.46°F) Short in circuit: 59.55°C (139.19°F) |
| Evaporator Target Temp | Target evaporator temperature / Min.: -327.68°C (-557.8°F) Max.: 327.67°C (621.8°F) |
Target evaporator temperature is displayed | - |
| Solar Sensor (D Side) | Driver side automatic light control sensor / Min.: 0, Max.: 255 |
Driver side automatic light control sensor value increases as brightness increases | - |
| Solar Sensor (P Side) | Front passenger side automatic light control sensor / Min.: 0, Max.: 255 |
Front passenger side automatic light control sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature is displayed while engine is warmed up | - |
| Duct Sensor (D Side) | Duct sensor (for driver side) / Min.: -12.7°C (9.14°F) Max.: 76.55°C (169.79°F) |
Actual duct temperature is displayed (for driver side) | - |
| Duct Sensor (P Side) | Duct sensor (for passenger side) / Min.: -12.7°C (9.14°F) Max.: 76.55°C (169.79°F) |
Actual duct temperature is displayed (for passenger side) | - |
| Set Temperature (D Side) | Driver side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT | Driver side actual set temperature is displayed | 18 to 32°C (0.5°C increments) (64.4 to 89.6 °F [0.9°F increments]) |
| Set Temperature (P Side) | Passenger side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT | Passenger side actual set temperature is displayed | 18 to 32°C (0.5°C increments) (64.4 to 89.6 °F [0.9°F increments]) |
| Hand Free Telephone | Handsfree telephone / OFF or ON | ON: Handsfree telephone is used OFF: Handsfree telephone is not used |
- |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 level Max.: 31 level |
Increases in range between 0 and 31 as blower motor speed increases | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) |
Adjusted ambient temperature is displayed | - |
| Emission Gas Sensor | Emission gas sensor / Min.: 0, Max.: 255 |
Increases as the gas amount increases | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse / for LHD Min.: 8, Max.: 31 for RHD Min.: 7, Max.: 30 |
for LHD:
for RHD:
|
- |
| Cool Air Bypass Pulse | Driver side cool air bypass servo motor target pulse / for LHD Min.: 19, Max.: 116 for RHD Min.: 6, Max.: 103 |
for LHD:
for RHD:
|
- |
| Compressor Speed | Compressor speed / Min.: 0, Max.: 65535 rpm |
Actual compressor speed is displayed | - |
| Compressor Target Speed | Compressor target speed / Min.: 0, Max.: 65535 rpm |
Compressor target speed is displayed | - |
| Rear Solar Sensor | Rear solar sensor / Min.: 0, Max.: 255 |
Rear solar sensor value increases as brightness increases | - |
| Emission Gas Nox Sensor | Emission gas NOx sensor / Min.: 0, Max.: 255 |
Increases as gas amount increases | - |
| Regulator Pressure Sensor | Refrigerant pressure sensor / Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual refrigerant pressure is displayed | - |
| Room Temp Sensor (Rear) | Rear room temperature sensor (for LH seat) / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual rear room temperature for LH seat is displayed | Open circuit: -6.5°C (20.3°F) Short circuit: 57.25°C (135.05°F) |
| Ambient Temp Sens (Rear) | Rear evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual rear evaporator temperature is displayed | Open in circuit: -29.7°C (-21.46°F) Short in circuit: 59.55°C (139.19°F) |
| Blower Motor Level (Rear) | Rear blower motor speed level / Min.: 0, Max.: 31 |
Increases in range between 0 to 31 as rear blower motor speed increases | - |
| Humidity Sensor | Humidity Sensor / Min.: 0%, Max.: 100% |
Actual room humidity is displayed | - |
| HOT A/M Servo Targ Pls(D) | Driver side HOT air mix servo motor target pulse / Min.: 87, Max.: 191 |
MAX HOT: 87 (pulse) MIN HOT: 191 (pulse) |
- |
| COOL A/M Servo Targ Pls(D) | Driver side COOL air mix servo motor target pulse / Min.: 90, Max.: 194 |
MAX COOL: 194 (pulse) MIN COOL: 90 (pulse) |
- |
| HOT A/M Servo Targ Pls(P) | Passenger side HOT air mix servo motor target pulse / Min.: 87, Max.: 191 |
MAX HOT: 87 (pulse) MIN HOT: 191 (pulse) |
- |
| COOL A/M Servo Targ Pls(P) | Passenger side COOL air mix servo motor target pulse / Min.: 90, Max.: 194 |
MAX COOL: 194 (pulse) MIN COOL: 90 (pulse) |
- |
| A/O Damper FACE Pos(D) | Driver side FACE air outlet servo motor target pulse / for LHD Min.: 7, Max.: 126 for RHD Min.: 32, Max.: 151 |
for LHD:
for RHD:
|
- |
| A/O Damper FOOT/DEF Pos(D) | Driver side FOOT/DEF air outlet servo motor target pulse / for LHD Min.: 86, Max.: 156 for RHD Min.: 26, Max.: 96 |
for LHD:
for RHD:
|
- |
| A/O Damper FACE Pos(P) | Passenger side FACE air outlet servo motor target pulse / for LHD Min.: 32, Max.: 151 for RHD Min.: 7, Max.: 126 |
for LHD:
for RHD:
|
- |
| A/O Damper FOOT/DEF Pos(P) | Passenger side FOOT/DEF air outlet servo motor target pulse / for LHD Min.: 26, Max.: 96 for RHD Min.: 86, Max.: 156 |
for LHD:
for RHD:
|
- |
| M/H Bypass HOT Targ Pls | Max hot bypass servo motor HOT target pulse / Min.: 18, Max.: 168 |
Shut: 18 (pulse) Open: 168 (pulse) |
- |
| M/H Bypass COOL Targ Pls | Max hot bypass servo motor COOL target pulse / for LHD Min.: 51, Max.: 63 for RHD Min.: 67, Max.: 78 |
for LHD:
for RHD:
|
- |
| Air Mix Servo Targ Pls(F&R D) | Driver side front A/C rear air flow air mix servo motor target pulse / for LHD Min.: 18, Max.: 103 for RHD Min.: 43, Max.: 128 |
for LHD:
for RHD:
|
- |
| Air Mix Servo Targ Pls(F&R P) | Passenger side front A/C rear air flow air mix servo motor target pulse / for LHD Min.: 43, Max.: 128 for RHD Min.: 18, Max.: 103 |
for LHD:
for RHD:
|
- |
| Air Outlet Servo Pls (F&R D) | Driver side front A/C rear air flow air outlet target pulse / for LHD Min.: 20, Max.: 119 for RHD Min.: 43, Max.: 142 |
for LHD:
for RHD:
|
- |
| Air Outlet Servo Pls (F&R P) | Passenger side front A/C rear air flow air outlet target pulse / for LHD Min.: 43, Max.: 142 for RHD Min.: 20, Max.: 119 |
for LHD:
for RHD:
|
- |
| Air Outlet Servo Pulse (R) | Rear air outlet servo motor target pulse (for LH side)/ Min.: 8, Max.: 37 |
Rear cooler ON: 37 (pulse) Air purifier ON: 8 (pulse) |
- |
| Air Outlet Servo Pulse (RP) | Rear air outlet servo motor target pulse (for RH side)/ Min.: 8, Max.: 37 |
Rear cooler ON: 37 (pulse) Air purifier ON: 8 (pulse) |
- |
| COOL Bypass Target Pulse (P) | Passenger side COOL air bypass servo motor target pulse / for LHD Min.: 6, Max.: 103 for RHD Min.: 19, Max.: 116 |
for LHD:
for RHD:
|
- |
| Emission Target Pulse (R) | Rear exhaust mode servo motor target pulse (for emission) / Min.: 8, Max.: 37 |
Emission mode: 37 (pulse) | - |
| Diffuse Target Pulse (R) | Rear exhaust mode servo motor target pulse (for diffusion) / Min.: 8, Max.: 46 |
Diffusion mode: 46 (pulse) | - |
| Room Temperature Sensor (RP) | Rear room temperature sensor (for RH seat) / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual rear room temperature for RH seat is displayed | Open circuit: -6.5°C (20.3°F) Short circuit: 57.25°C (135.05°F) |
| Set Temperature (Rear D side) | Rear driver side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT | Rear driver side actual set temperature is displayed | 18 to 32°C (0.5°C increments) (64.4 to 89.6 °F [0.9°F increments]) |
| Set Temperature (Rear P side) | Rear passenger side set temperature / MAX COLD, 18.0°C (64.4°F) to 32.0°C (89.6°F) or MAX HOT | Rear passenger side actual set temperature is displayed | 18 to 32°C (0.5°C increments) (64.4 to 89.6 °F [0.9°F increments]) |
| Estimated Temp (Rear D side) | Rear driver side estimated temperature / Min.: -358.4°C (-613.12°F) Max.: 358.4°C (677.12°F) |
Rear driver side estimated temperature displayed | - |
| Estimated Temp (Rear P side) | Rear passenger side estimated temperature / Min.: -358.4°C (-613.12°F) Max.: 358.4°C (677.12°F) |
Rear passenger side estimated temperature displayed | - |
| Add Foot Air in FACE Mode | Add foot air in face mode / ON, OFF | Customized value will be displayed | - |
| ECO MODE Cancel | ECO MODE Cancel / ON, OFF | Customized value will be displayed | - |
| Shift Set Temperature | Shift set temperature / 2C incr, 1C incr, Normal, 1C decr, 2C decr | Customized value will be displayed | - |
| Air Inlet Mode | Air inlet mode / Auto, Manual | Customized value will be displayed | - |
| Compressor Mode | Compressor mode / Auto, Manual | Customized value will be displayed | - |
| Emission Gas Sensor Shift | Emission gas sensor shift / Mu More, More, Li More, Normal, Li Less, Less, Mu Less | Customized value will be displayed | - |
| Button Press Buzzer | Button press buzzer / ON, OFF | Customized value will be displayed | - |
| Foot/DEF Auto Mode | FOOT/DEF auto mode / ON, OFF | Customized value will be displayed | - |
| Foot/DEF Auto Blow Up | FOOT/DEF auto blower up function / ON, OFF | Customized value will be displayed | - |
| Filter Sensor | Filter sensor / Less, Normal, More | Customized value will be displayed | - |
| Rear A/P HI Set | Rear A/P HI Set auto mode / ON, OFF | Customized value will be displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / 3C incr, 2C incr, 1C incr, Normal, 1C decr, 2C decr, 3C decr | Customized value will be displayed | - |
| Batt Cool Down Servo Targ Pls | HV battery cool down servo motor target pulse/ Min.: 8, Max.: 30 |
A/C intake air position: 8 Interior intake air position: 30 |
- |
| Infrared Rays Sensor 1 | Infrared ray sensor 1 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Infrared Rays Sensor 2 | Infrared ray sensor 2 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Infrared Rays Sensor 3 | Infrared ray sensor 3 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Infrared Rays Sensor 4 | Infrared ray sensor 4 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Infrared Rays Sensor 5 | Infrared ray sensor 5 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Infrared Rays Sensor 6 | Infrared ray sensor 6 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Infrared Rays Sensor 7 | Infrared ray sensor 7 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Infrared Rays Sensor 8 | Infrared ray sensor 8 Min.: 1°C (33.8°F) Max.: 50.5°C (122.9°F) |
Actual human body temperature is displayed | Open in circuit: 1°C (33.8°F) Short in circuit: 50.5°C (122.9°F) |
| Humidity Level | Status of humidity sensor / Normal humidity, Low humidity |
Actual humidity status is displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 |
Number of DTCs will be displayed | - |
ACTIVE TEST
Tech Tips
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Test.
Connect the GTS to the DLC3.
Turn the power switch ON (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
According to the display on the GTS, perform the "Active Test".
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor target speed | Min.: 0, Max.: 65535 rpm | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | OFF or ON | - |
| Deicer Relay (Front) | Deicer relay (Front) | OFF or ON | - |
| Mirror Heater Relay | Mirror heater relay | OFF or ON | - |
| Rear A/C Mag Valve | Rear A/C magnetic valve | OFF or ON | - |
| Water Pump | Water pump relay | OFF or ON | - |
| Electrical Fan | Electrical fan | OFF or ON | - |
| Heater Active Level | Heater active level | Min.: 0, Max.: 3 | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse | for LHD Min.: 8, Max.: 31 for RHD Min.: 7, Max.: 30 |
- |
| Cool Air Bypass Pulse | Driver side cool air bypass pulse | Min.: 19, Max.: 116 | - |
| Hot A/M Servo Pulse(D) | HOT Air mix servo motor pulse (Driver side) | Min.: 87, Max.: 191 | - |
| Cool A/M Servo Pulse(D) | COOL Air mix servo motor pulse (Driver side) | Min.: 90, Max.: 194 | - |
| Hot A/M Servo Pulse(P) | HOT Air mix servo motor pulse (Passenger side) | Min.: 87, Max.: 191 | - |
| Cool A/M Servo Pulse(P) | COOL Air mix servo motor pulse (Passenger side) | Min.: 90, Max.: 194 | - |
| Face A/O Servo Pulse(D) | FACE Air outlet servo motor pulse (Driver side) | for LHD Min.: 7, Max.: 126 for RHD Min.: 32, Max.: 151 |
- |
| Foot A/O Servo Pulse(D) | FOOT Air outlet servo motor pulse (Driver side) | for LHD Min.: 86, Max.: 156 for RHD Min.: 26, Max.: 96 |
- |
| Face A/O Servo Pulse(P) | FACE Air outlet servo motor pulse (Passenger side) | for LHD Min.: 32, Max.: 151 for RHD Min.: 7, Max.: 126 |
- |
| Foot A/O Servo Pulse(P) | FOOT Air outlet servo motor pulse (Passenger side) | for LHD Min.: 26, Max.: 96 for RHD Min.: 86, Max.: 156 |
- |
| M/H Bypass Hot Servo Pls | M/H bypass HOT servo motor pulse | Min.: 18, Max.: 168 | - |
| M/H Bypass Cool Servo Pls | M/H bypass COOL servo motor pulse | for LHD Min.: 51, Max.: 63 for RHD Min.: 67, Max.: 78 |
- |
| A/M Servo Pulse(F&R D) | Air mix servo motor pulse (Front A/C rear air flow driver side) | for LHD Min.: 18, Max.: 103 for RHD Min.: 43, Max.: 128 |
- |
| A/M Servo Pulse(F&R P) | Air mix servo motor pulse (Front A/C rear air flow passenger side) | for LHD Min.: 43, Max.: 128 for RHD Min.: 18, Max.: 103 |
- |
| A/O Servo Pulse(F&R D) | Air outlet servo motor pulse (Front A/C rear air flow driver side) | for LHD Min.: 20, Max.: 119 for RHD Min.: 43, Max.: 142 |
- |
| A/O Servo Pulse(F&R P) | Air outlet servo motor pulse (Front A/C rear air flow passenger side) | for LHD Min.: 43, Max.: 142 for RHD Min.: 20, Max.: 119 |
- |
| A/O Servo Pulse(Rr D) | Air outlet servo motor pulse (Rear driver side) | for LHD Min.: 6, Max.: 28 for RHD Min.: 14, Max.: 36 |
- |
| A/O Servo Pulse(Rr P) | Air outlet servo motor pulse (Rear passenger side) | for LHD Min.: 14, Max.: 36 for RHD Min.: 6, Max.: 28 |
- |
| Cool Air Bypass Pls(P) | Cool air bypass pulse (Passenger side) | for LHD Min.: 6, Max.: 103 for RHD Min.: 19, Max.: 116 |
- |
| Emission Pulse(R) | Emission pulse (Rear) | Min.: 8, Max.: 37 | - |
| Diffuse Pulse(R) | Diffuse pulse (Rear) | Min.: 8, Max.: 46 | - |
| Batt Cool Down Servo Targ Pls | HV battery cool down servo motor target pulse | Min.: 8, Max.: 30 | - |
| Rear Blower Motor | Rear blower motor | Min.: 0, Max.: 31 | - |
| Ion Generator | Ion generator | OFF or ON | - |