SHOULDER BELT ANCHORAGE SWITCH INSPECTION

PROCEDURE


  1. INSPECT HEIGHT ADJUSTABLE ANCHOR SWITCH (for LH Side)

    A000TN3E08
    *a UP
    *b DW
    *c DOWN

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (UL) - 4 (UP) UP Below 1 Ω
      2 (DW) - 4 (UP) UP 10 kΩ or higher
      2 (DW) - 3 (UL) DOWN Below 1 Ω
      3 (UL) - 4 (UP) DOWN 10 kΩ or higher

      If the result is not as specified, replace the height adjustable anchor switch.

  2. INSPECT HEIGHT ADJUSTABLE ANCHOR SWITCH (for RH Side)

    A000TN3E09
    *a UP
    *b DW
    *c DOWN

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      2 (UP) - 3 (UL) UP Below 1 Ω
      2 (UP) - 4 (DW) UP 10 kΩ or higher
      3 (UL) - 4 (DW) DOWN Below 1 Ω
      2 (UP) - 3 (UL) DOWN 10 kΩ or higher

      If the result is not as specified, replace the height adjustable anchor switch.