COMBINATION METER DISASSEMBLY

PROCEDURE


  1. REMOVE NO. 1 COMBINATION METER BRACKET


    1. A000X0O

      Remove the 4 screws and No. 1 combination meter bracket.

  2. REMOVE COMBINATION METER GLASS

    A000XPC

    1. Remove the 2 screws.

    2. Detach the 6 claws and remove the combination meter glass.

  3. REMOVE COMBINATION METER COVER

    A000UFL

    1. Remove the 10 screws and combination meter cover.

  4. REMOVE METER DISPLAY PANEL


    1. Lift the 3 connector locks upward to release the locks and disconnect the 2 wire harnesses from the 3 connectors.

      Note


      • Do not remove the connector lock from the meter ECU.

      • Do not forcibly pull the wire harness from the connector.

      • Disconnect the wire harness from the connector by holding both ends and pulling straight up.

      • Do not scratch or dirty the contacts of the wire harness.

    2. Remove the meter display panel from the meter ECU.

      A000VRIE02
      Text in Illustration
      *1 Connector Lock *2 Wire Harness
      A000Y24 Upward - -