ДАТЧИК ПОЛОЖЕНИЯ РАСПРЕДВАЛА УСТАНОВКА

PROCEDURE


  1. INSTALL VVT SENSOR


    1. A001FRTE03
      *1 BANK 2
      *2 BANK 1

      Install the 4 VVT sensors with the 4 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Connect the 4 VVT sensor connectors.

  2. INSTALL AIR CLEANER ASSEMBLY RH

    A0019Q9

    1. Install the air cleaner case with the 2 nuts and clip.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    2. Install the element to the air cleaner case.

    3. A001CQF

      Install the air cleaner cap to the air cleaner hose assembly with the hose clamp.

      Torque:
      3.8 N*m  { 38 kgf*cm, 34 in.*lbf }

      Note

      Insert the protrusion of the air cleaner hose into the hole of the hose clamp.

      Tech Tips

      The hose clamp can be tightened within the range of 2.0 N*m (20 kgf*cm. 18 in.*lbf) to 5.5 N*m (56 kgf*cm. 49 in.*lbf).

    4. Install the air cleaner cap to the air cleaner case with the 2 clips.

    5. Connect the MAF meter connector.

  3. INSTALL AIR CLEANER ASSEMBLY LH

    A001BWS

    1. Install the air cleaner case with the 2 nuts and clip.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    2. Install the element to the air cleaner case.

    3. A0019B3

      Install the air cleaner cap to the air cleaner hose assembly with the hose clamp.

      Torque:
      3.8 N*m  { 38 kgf*cm, 34 in.*lbf }

      Note

      Insert the protrusion of the air cleaner hose into the hole of the hose clamp.

      Tech Tips

      The hose clamp can be tightened within the range of 2.0 N*m (20 kgf*cm. 18 in.*lbf) to 5.5 N*m (56 kgf*cm. 49 in.*lbf).

    4. Install the air cleaner cap to the air cleaner case with the 2 clips.

    5. Connect the MAF meter connector.

  4. INSTALL NO. 1 AIR CLEANER INLET

    Click here

  5. INSTALL AIR CLEANER INLET COVER SUB-ASSEMBLY

    Click here

  6. INSTALL V-BANK COVER SUB-ASSEMBLY

    Click here