ДАТЧИК ПОЛОЖЕНИЯ РАСПРЕДВАЛА СНЯТИЕ

PROCEDURE


  1. REMOVE V-BANK COVER SUB-ASSEMBLY

    Click here

  2. REMOVE AIR CLEANER INLET COVER SUB-ASSEMBLY

    Click here

  3. REMOVE NO. 1 AIR CLEANER INLET

    Click here

  4. REMOVE AIR CLEANER ASSEMBLY LH

    A001F01

    1. Disconnect the MAF meter connector.

    2. Remove the 2 clips, hose clamp and air cleaner cap.

    3. Remove the element from the air cleaner case.

    4. A001BWS

      Remove the 2 nuts, clip and air cleaner case.

  5. REMOVE AIR CLEANER ASSEMBLY RH

    A001BM3

    1. Disconnect the MAF meter connector.

    2. Remove the 2 clips, hose clamp and air cleaner cap.

    3. Remove the element from the air cleaner case.

    4. A0019Q9

      Remove the 2 nuts, clip and air cleaner case.

  6. REMOVE VVT SENSOR


    1. A001FRTE03
      *1 BANK 2
      *2 BANK 1

      Disconnect the 4 VVT sensors.

    2. Remove the 4 bolts and 4 VVT sensors.