OUTER MIRROR SWITCH INSPECTION

PROCEDURE


  1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for LHD, w/o Automatic Retractable Mirror)


    1. B001GK0C03
      *a Mirror Retract Switch
      *b Mirror Select Switch
      *c Mirror Surface Adjust Switch
      *d Component without harness connected (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        11 (B) - 14 (MF)

        12 (E) - 13 (MR)

        Extended position Below 1 Ω

        11 (B) - 13 (MR)

        12 (E) - 14 (MF)

        Retracted position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch and mirror surface adjust switch.


      1. Turn the mirror select switch to the L position.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for Left Side)
        Tester Connection Condition Specified Condition

        9 (MLV) - 11 (B)

        6 (M+) - 12 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        6 (M+) - 11 (B)

        9 (MLV) - 12 (E)

        Down Below 1 Ω
        Off 10 kΩ or higher

        10 (MLH) - 11 (B)

        6 (M+) - 12 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        6 (M+) - 11 (B)

        10 (MLH) - 12 (E)

        Right Below 1 Ω
        Off 10 kΩ or higher
      3. Turn the mirror select switch to the R position.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for Right Side)
        Tester Connection Condition Specified Condition

        8 (MRV) - 11 (B)

        6 (M+) - 12 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        6 (M+) - 11 (B)

        8 (MRV) - 12 (E)

        Down Below 1 Ω
        Off 10 kΩ or higher

        7 (MRH) - 11 (B)

        6 (M+) - 12 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        6 (M+) - 11 (B)

        7 (MRH) - 12 (E)

        Right Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    3. Inspect the switch illumination.

      Apply battery voltage between the terminals of the light, and check the operation of the light.

      OK
      Battery Connection Specified Condition

      Battery positive (+) - 15 (ILL+)

      Battery negative (-) - 16 (ILL-)

      Light comes on

      If the result is not as specified, replace the outer mirror switch assembly.

  2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for LHD, w/ Automatic Retractable Mirror)


    1. B001FIWC03
      *a Mirror Retract Switch
      *b Mirror Surface Adjust Switch
      *c Mirror Select Switch
      *d

      Component without harness connected

      (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        11 (MAT) - 10 (E)

        8 (MR) - 10 (E)

        Driving position 10 kΩ or higher
        11 (MAT) - 10 (E) AUTO position Below 1 Ω
        8 (MR) - 10 (E) Retracted position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (MSWR) - 14 (MSW) R Below 10 Ω
        L 90 to 110 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    3. Check the mirror surface adjust switch.


      1. Select the mirror select switch to the L position or R position.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (MSWR) - 13 (B) Mirror adjust switch pressed up 90 to 110 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed down 437 to 503Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed left 744 to 856Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed right 225 to 275Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    4. Check the switch illumination.


      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK
        Battery Connection Specified Condition

        Battery positive (+) - 6 (ILL+)

        Battery negative (-) - 15 (ILL-)

        Light comes on

        If the result is not as specified, replace the outer mirror switch assembly.

  3. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for RHD, w/o Automatic Retractable Mirror)


    1. B001CTUC01
      *a Mirror Retract Switch
      *b Mirror Select Switch and Mirror Surface Adjust Switch
      *c Component without harness connected (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        2 (MF) - 15 (B)

        16 (MR) - 1 (E)

        Extended position Below 1 Ω

        16 (MR) - 15 (B)

        2 (MF) - 1 (E)

        Retracted position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch and mirror surface adjust switch.


      1. Select the mirror select switch to the L position.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for left side)
        Tester Connection Condition Specified Condition

        12 (MLV) - 15 (B)

        9 (M+) - 1 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        9 (M+) - 15 (B)

        12 (MLV) - 1 (E)

        Down Below 1 Ω
        Off 10 kΩ or higher

        13 (MLH) - 15 (B)

        9 (M+) - 1 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        9 (M+) - 15 (B)

        13 (MLH) - 1 (E)

        Right Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

      3. Select the mirror select switch to the R position.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance (for right side)
        Tester Connection Condition Specified Condition

        10 (MRV) - 15 (B)

        9 (M+) - 1 (E)

        Up Below 1 Ω
        Off 10 kΩ or higher

        9 (M+) - 15 (B)

        10 (MRV) - 1 (E)

        Down Below 1 Ω
        Off 10 kΩ or higher

        11 (MRH) - 15 (B)

        9 (M+) - 1 (E)

        Left Below 1 Ω
        Off 10 kΩ or higher

        9 (M+) - 15 (B)

        11 (MRH) - 1 (E)

        Right Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    3. Check the switch illumination.


      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK
        Battery Connection Specified Condition

        Battery positive (+) - 14 (ILL+)

        Battery negative (-) - 8 (ILL-)

        Light comes on

        If the result is not as specified, replace the outer mirror switch assembly.

  4. INSPECT OUTER MIRROR SWITCH ASSEMBLY (for RHD, w/ Automatic Retractable Mirror)


    1. B001F2OC02
      *a Mirror Retract Switch
      *b Mirror Select Switch and Mirror Surface Adjust Switch
      *c

      Component without harness connected

      (Outer Mirror Switch Assembly)

      Check the mirror retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        11 (MAT) - 10 (E)

        17 (MR) - 10 (E)

        Extended position 10 kΩ or higher
        11 (MAT) - 10 (E) AUTO position Below 1 Ω
        17 (MR) - 10 (E) Retracted position Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Check the mirror select switch and mirror surface adjust switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (MSWR) - 13 (MSW) R Below 10 Ω
        L 90 to 110 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

      2. Select the mirror select switch to the L position or R position.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12 (MSWR) - 15 (B) Mirror adjust switch pressed up 90 to 110 Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed down 437 to 503Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed left 744 to 856Ω
        Off 10 kΩ or higher
        Mirror adjust switch pressed right 225 to 275Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    3. Check the switch illumination.


      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK
        Battery Connection Specified Condition

        Battery positive (+) - 14 (ILL+)

        Battery negative (-) - 16 (ILL-)

        Light comes on

        If the result is not as specified, replace the outer mirror switch assembly.