POWER WINDOW CONTROL SYSTEM All Power Windows do not Operate with Driver Side Door Key Cylinder or Wireless Transmitter

DESCRIPTION



CAUTION / NOTICE / HINT

Note


  • These functions are set through the customize function, as they are off by default Click here.

  • The power window control system uses the LIN communication system and CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the power window control system after confirming that the communication systems are functioning properly Click here.

  • If the main body ECU (multiplex network body ECU) is replaced, refer to the Service Bulletin.

  • As the door control battery is installed between the vehicle battery and main body ECU (multiplex network body ECU), first perform the inspections in On-Vehicle Inspection to confirm that there are no malfunctions in the power source circuit for the main body ECU (multiplex network body ECU) before performing this troubleshooting procedure.*


    • *: w/ Door Control Battery

PROCEDURE


  1. CHECK BASIC FUNCTION (WIRELESS AND POWER DOOR LOCK CONTROL SYSTEM)


    1. Check that the wireless door lock/unlock function operates normally.


    2. Check that the key-linked lock/unlock function operates normally Click here.

    3. Check that the wireless transmitter and driver door key cylinder (key-linked switch) lock and unlock all the doors normally.


      Result
      Result Proceed to
      Wireless door lock/unlock function and key-linked lock/unlock function operate normally A
      Wireless door lock/unlock function does not operate normally (w/ Entry and Start System) B
      Wireless door lock/unlock function does not operate normally (w/o Entry and Start System) C
      Key-linked lock/unlock function does not operate normally D

    B
    C
    D
    A
  2. CHECK MANUAL UP/DOWN FUNCTION


    1. Check that the manual up and down functions using the multiplex network master switch assembly and power window regulator switch assembly can operate all the power windows Click here.

      OK
      Manual up and down functions are normal.

    NG
    OK
  3. CHECK REMOTE UP/DOWN FUNCTION


    1. Check that the remote up and down functions using the multiplex network master switch assembly can operate all the power windows Click here.

      OK
      Remote up and down functions are normal.

    OK
    NG