HEATER ASSEMBLY DISASSEMBLY

PROCEDURE


  1. REMOVE AIR DUCT

    A01XJHP

    1. Remove the screw and air duct.

  2. REMOVE HEATER WATER HOSE

    A01XEFZ

    1. Using pliers, grip the claw of the clip and slide the clip to disconnect the heater hose.

      Note


      • Do not apply excessive force to the hose.

      • Prepare a drain pan or cloth in case the coolant leaks.

  3. REMOVE WATER HOSE SUB-ASSEMBLY C (for Dual Air Conditioning System)

    A01XDXN

    1. Using pliers, grip the claw of the clip and slide the clip to disconnect the water hose sub-assembly C.

      Note


      • Do not apply excessive force to the hose.

      • Prepare a drain pan or cloth in case the coolant leaks.

  4. REMOVE HEATER WATER HOSE INLET K (for Single Air Conditioning System)

    A01XDXN

    1. Using pliers, grip the claw of the clip and slide the clip to disconnect the heater water hose inlet K.

      Note


      • Do not apply excessive force to the hose.

      • Prepare a drain pan or cloth in case the coolant leaks.