COMBUSTION TYPE POWER HEATER SYSTEM, Diagnostic DTC:010, 011

DTC Code DTC Name
010 Over Voltage Shutoff
011 Under Voltage Shutoff

DESCRIPTION

DTC Code DTC Detection Condition Trouble Area
010 Battery voltage is 14 V or more for 20 seconds or more.
  • Harness or connector

  • Battery

  • Heater assembly

011 Battery voltage is 10 V or less for 20 seconds or more.
  • Harness or connector

  • Battery

  • Heater assembly

WIRING DIAGRAM

B001EFAE05

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - BATTERY AND BODY GROUND)


    1. B001EXFE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Heater Assembly)

      Disconnect the heater assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A97-5 (B) - Body ground Always 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A97-1 (E) - Body ground Always Below 1 Ω

    OK
    NG