GENERATOR REMOVAL

PROCEDURE


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note


    • After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

    • When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  2. REMOVE FAN AND GENERATOR V BELT


    1. Remove the fan and generator V belt Click here.

  3. REMOVE FRONT FENDER APRON SEAL RH

    Click here

  4. REMOVE AIR CLEANER CAP SUB-ASSEMBLY

    Click here

  5. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  6. REMOVE AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  7. REMOVE NO. 1 AIR HOSE

    Click here

  8. REMOVE GENERATOR


    1. B001EDY

      Disconnect the generator connector.

    2. Remove the terminal cap.

    3. Remove the nut and disconnect the generator wire.

    4. Remove the 2 bolts and generator.