GENERATOR(for 130 A Type) INSTALLATION

PROCEDURE


  1. INSTALL GENERATOR ASSEMBLY


    1. Install the generator bracket to the generator assembly with the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    2. Install the generator assembly with the 2 bolts.

      Torque:
      43 N*m  { 438 kgf*cm, 32 ft.*lbf }
    3. Attach the clamp and connect the wire harness to the generator bracket.

    4. Connect the wire harness to the generator assembly with the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    5. Connect the wire harness to terminal B with the nut.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    6. Install the terminal cap.

    7. Connect the connector to the generator assembly.

  2. INSTALL FAN AND GENERATOR V BELT

    Click here

  3. INSTALL NO. 2 INTERCOOLER AIR HOSE

    Click here

  4. INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY

    Click here

  5. INSTALL BATTERY TRAY

  6. INSTALL BATTERY

  7. INSTALL BATTERY HOLD DOWN CLAMP


    1. Install the battery hold down clamp with the 2 nuts and 2 battery clamp bolts.

      Torque:
      5.4 N*m  { 55 kgf*cm, 48 in.*lbf }
  8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here