PROCEDURE
INSTALL FRONT CORNER ULTRASONIC SENSOR RETAINER
Tech Tips
Perform this step only when necessary.
If a front corner ultrasonic sensor retainer has been removed, replace it with a new one. Install the front corner ultrasonic sensor with a new front corner ultrasonic sensor retainer as a set to the front bumper cover.
Use the same procedure to install the front corner ultrasonic sensor retainer on the other side.
Clean the front bumper cover surface.
Remove the remaining double-sided tape from the front bumper cover.
Wipe off any tape adhesive residue with cleaner.
| *a | 17 mm (0.67 in.) |
Cover the sensor installation hole with a 17 mm (0.67 in.) square piece of tape.
| *a | Mark-off Line |
|
Primer |
Using a brush or felt, apply primer or equivalent to the front corner ultrasonic sensor retainer installation area.
Note
Use a clean brush or felt.
Do not touch the front bumper cover until the primer has dried.
Using a heat light, heat the front bumper cover.
| Standard | ||||
|---|---|---|---|---|
|
Note
Do not heat the front bumper cover excessively.
Peel off the release paper from a new front corner ultrasonic sensor retainer.
Align the front corner ultrasonic sensor retainer with the alignment line and set it on the front bumper cover as shown in the illustration.
Note
The double-sided tape of a front corner ultrasonic sensor retainer will deteriorate if it is detached. Make sure to replace the front corner ultrasonic sensor retainer with a new one when reattachment is necessary.
Tech Tips
Align the connector side with the protrusion of the mark and install it.
Press the front corner ultrasonic sensor retainer with a force of 30 N (3.0 kgf) for 3 seconds and install the front corner ultrasonic sensor retainer firmly so that there is no clearance between the front corner ultrasonic sensor retainer and front bumper cover.
| *a | Alignment Line | *b | Connector Side |
| *c | Protrusion of the mark | - | - |
INSTALL FRONT CORNER ULTRASONIC SENSOR
Note
When reusing the ultrasonic sensor, make sure that each ultrasonic sensor is returned to its original position.
Tech Tips
Use the same procedure to install the front corner ultrasonic sensor on the other side.
Attach the 2 claws to install the front corner ultrasonic sensor.
Connect the connector.
INSTALL FRONT CENTER ULTRASONIC SENSOR RETAINER
Tech Tips
Use the same procedure described for the front corner ultrasonic sensor retainer.
INSTALL FRONT CENTER ULTRASONIC SENSOR
Tech Tips
Use the same procedure described for the front corner ultrasonic sensor.
INSTALL FRONT BUMPER COVER