PROCEDURE
OPERATION CHECK
Disconnect the vacuum hose from the vacuum pump.
| *a | Vacuum Gauge |
Connect the hose of the vacuum gauge to the vacuum pump.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, check the negative pressure of the vacuum pump.
| Standard pressure |
|---|
| Higher than 87 kPa (650 mmHg, 25.6 in.Hg) |
Tech Tips
It is necessary to replace the vacuum pump every 200000 km (124000 miles).
Remove the vacuum gauge from the vacuum pump.
Connect the vacuum hose to the vacuum pump.