PROCEDURE
INSPECT NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY
| *a | Component without harness connected (No. 2 Height Control Valve) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||
|---|---|---|---|---|---|---|---|
|
Check the operating sound of the height control valve when battery voltage is applied to the terminals.
| OK | |||||
|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 height control valve sub-assembly.