PROCEDURE
INSPECT NO. 2 COMBINATION SWITCH ASSEMBLY
| *a | Component without harness connected (No. 2 Combination Switch Assembly (Center Differential Lock Switch)) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 combination switch assembly (center differential lock switch).
| *a | Component without harness connected (No. 2 Combination Switch Assembly (Center Differential Lock Switch)) |
Apply battery voltage between the terminals of the No. 2 combination switch assembly (center differential lock switch), and check the illumination condition of the No. 2 combination switch assembly (center differential lock switch).
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 combination switch assembly (center differential lock switch).
INSPECT CENTER DIFFERENTIAL LOCK SWITCH
| *a | Component without harness connected (Center Differential Lock Switch) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the center differential lock switch.
| *a | Component without harness connected (Center Differential Lock Switch) |
Apply battery voltage between the terminals of the switch, and check the illumination condition of the center differential lock switch.
| Standard | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the center differential lock switch.