DESCRIPTION
When the glass breakage sensor detects that the quarter window glass* or back door glass is tapped or broken, the sensor will set off the alarm for 30 seconds.
*: for 5 Door
WIRING DIAGRAM
for 3 Door:
for 5 Door:
CAUTION / NOTICE / HINT
Note
w/ Entry and Start System:
If the main body ECU (multiplex network body ECU) is replaced, refer to the Service Bulletin.
PROCEDURE
READ VALUE USING GTS (Sealed Glas Brak Sen)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Sealed Glas Brak Sen | Glass breakage sensor connecting | With or Without | With: Glass breakage sensor operating Without: Glass breakage sensor not operating |
- |
| OK |
|---|
| "With" (glass breakage sensor operating) appears on GTS screen. |
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
CHECK HARNESS AND CONNECTOR (GLASS BREAKAGE SENSOR - MAIN BODY ECU [MULTIPLEX NETWORK BODY ECU] AND BODY GROUND)
*1: for 5 Door
*2: w/ Glass Hatch Opener System
*3: w/o Glass Hatch Opener System
Disconnect the G218 main body ECU (multiplex network body ECU) connector.
Disconnect the R25 quarter window assembly LH (glass breakage sensor) connector.*1
Disconnect the Q20 quarter window assembly RH (glass breakage sensor) connector.*1
Disconnect the Y2*2 or X8*3 back door glass (glass breakage sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||
|
||||||||||||||||||||||||
|
||||||||||||||||||||||||
|
| Result | ||||
|---|---|---|---|---|
|
| OK (for 3 Door) |
|
GO TO STEP 5 Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK (for 5 Door) |
|
INSPECT QUARTER WINDOW ASSEMBLY LH (GLASS BREAKAGE SENSOR)
Disconnect the quarter window assembly LH (glass breakage sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE QUARTER WINDOW ASSEMBLY LH (GLASS BREAKAGE SENSOR) Click here |
| OK |
|
INSPECT QUARTER WINDOW ASSEMBLY RH (GLASS BREAKAGE SENSOR)
Disconnect the quarter window assembly RH (glass breakage sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE QUARTER WINDOW ASSEMBLY RH (GLASS BREAKAGE SENSOR) Click here |
| OK |
|
CHECK BACK DOOR GLASS (GLASS BREAKAGE SENSOR)
Disconnect the Y2*1 or X8*2 back door glass (glass breakage sensor) connector.
*1: w/ Glass Hatch Opener System
*2: w/o Glass Hatch Opener System
| *A | w/ Glass Hatch Opener System |
| *B | w/o Glass Hatch Opener System |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here |
| NG |
|
REPLACE BACK DOOR GLASS (GLASS BREAKAGE SENSOR) w/ Glass Hatch Opener System: Click here w/o Glass Hatch Opener System: Click here |