METER / GAUGE SYSTEM Operating Light Control Rheostat does not Change Light Brightness

DESCRIPTION

When the light control rheostat knob is turned right, the combination meter and vehicle interior illumination will become brighter. When the light control rheostat knob is turned left, the combination meter and vehicle illumination will dim.

WIRING DIAGRAM

Figure 1. except 5L-E

B001IBEE07

Figure 2. for 5L-E

B001DQZE01

PROCEDURE


  1. READ VALUE USING GTS (TAIL CANCEL SW, RHEOSTAT VALUE)


    1. Using the GTS, read the Data List Click here.

      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Tail Cancel SW* Tail cancel switch/OFF or ON OFF: Tail cancel switch off -
      ON: Tail cancel switch on
      Rheostat value Light control rheostat switch input/Min.: 0, Max.: 100 Light control rheostat switch is fully turned right (0) → fully turned left (100) Unit: %

      • *: w/ TAIL Cancel Switch

      OK
      Light brightness can be changed within specified range by manual operation.

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH [LIGHT CONTROL RHEOSTAT])


    1. Disconnect the G304*1, G6*2 combination meter assembly connector.


      • *1: except 5L-E

    2. Disconnect the G16 trip switch (light control rheostat) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (except 5L-E)
      for LHD
      Tester Connection Condition Specified Condition
      G304-35 (TC) - G16-6 (TC)* Always Below 1 Ω
      G304-33 (SW1) - G16-5 (T) Always Below 1 Ω
      G304-34 (SW2) - G16-7 (RV) Always Below 1 Ω
      G304-1 (SW3) - G16-1 (E) Always Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      G304-35 (TC) - G16-7 (TC)* Always Below 1 Ω
      G304-33 (SW1) - G16-8 (T) Always Below 1 Ω
      G304-34 (SW2) - G16-6 (RV) Always Below 1 Ω
      G304-1 (SW3) - G16-4 (E) Always Below 1 Ω

      • *: w/ TAIL Cancel Switch

      Standard Resistance (for 5L-E)
      for LHD
      Tester Connection Condition Specified Condition
      G6-6 (SW1) - G16-5 (T) Always Below 1 Ω
      G6-7 (SW2) - G16-7 (RV) Always Below 1 Ω
      G6-22 (SW3) - G16-1 (E) Always Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      G6-6 (SW1) - G16-8 (T) Always Below 1 Ω
      G6-7 (SW2) - G16-6 (RV) Always Below 1 Ω
      G6-22 (SW3) - G16-4 (E) Always Below 1 Ω

    NG
    OK
  3. CHECK COMBINATION METER ASSEMBLY


    1. Replace the combination meter assembly with a new or normally operating one. Perform an operation inspection.

      OK
      Combination meter assembly operates normally.

    OK
    NG