PROCEDURE
REMOVE FAN AND GENERATOR V BELT
Use the hexagonal part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the fan and generator V belt. Then remove the fan and generator V belt.
Note
When removing the fan and generator V belt, do not use the bolt of the idle pulley.
Tech Tips
After removing the fan and generator V belt, move the tensioner upward to the maximum amount.
REMOVE TENSIONER PULLEY
Note
Perform the following procedure when it is necessary to replace the tensioner pulley.
Remove the bolt, dust seal and tensioner pulley.