KNOCK SENSOR INSTALLATION

CAUTION / NOTICE / HINT

Tech Tips

Perform "Inspection After Repairs" after replacing the knock sensor Click here.

PROCEDURE


  1. INSTALL KNOCK SENSOR

    Tech Tips

    Perform "Inspection After Repairs" after replacing the knock sensor Click here.


    1. A01XEWX

      Install the knock sensor with the bolt.

      Torque:
      20 N*m  { 204 kgf*cm, 15 ft.*lbf }
      Text in Illustration
      B001CHY Front

      Note

      Make sure that the knock sensor is at the correct angle when installing.

    2. Connect the knock sensor connector.

  2. INSTALL INTAKE MANIFOLD

    Click here