INTAKE AIR TEMPERATURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT INTAKE AIR TEMPERATURE SENSOR


    1. Measure the resistance according to the value(s) in the table below.

      A01XJ8ZE05
      Text in Illustration
      *a

      Component without harness connected

      (Intake Air Temperature Sensor)

      *b Resistance
      *c Temperature *d Acceptable Range
      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 2.21 to 2.65 kΩ
      60°C (140°F) 0.54 to 0.62 kΩ

      CAUTION:


      • Do not put your hands in the water warmed up during the inspection.

      • Touching the hot water may result in burns.

      Note

      When checking the intake air temperature sensor in water, do not allow water to contact the terminals. After completing the check, dry the intake air temperature sensor.

      If the result is not as specified, replace the intake air temperature sensor.