1GD-FTV INTAKE / EXHAUST SERVICE DATA

INTAKE SYSTEM
Turbocharger pressure Standard pressure (Gauge Pressure)

11.4 to 47.2 kPa (0.1 to 0.5 kgf/cm2, 1.7 to 6.8 psi)

INTAKE MANIFOLD
Item Tester Connection Condition Specified Condition
Vacuum switching valve (for Swirl Control Valve) 1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 10 kΩ or higher
2 - Body ground 10 kΩ or higher
EXHAUST MANIFOLD W/ TURBOCHARGER
Axial play of turbine shaft Standard 0.11 mm (0.00433 in.)
Turbocharger nozzle vane control actuator Condition 20°C (68°F) 1 to 100 Ω
EXHAUST PIPE
Compression spring Minimum length 38.5 mm (1.52 in.)