INTAKE MANIFOLD INSPECTION

PROCEDURE


  1. INSPECT INTAKE MANIFOLD

    A01XEAP

    Note

    Do not adjust the adjusting screw or 2 actuator installation bolts.


    1. A01XIQ2

      Check the operation of the swirl control valve.


      1. Check that the valve is fully opened under normal conditions.

      2. Connect a vacuum pump to the control valve. Check that the valve is fully closed when a negative pressure of 66.7 kPa (500 mmHg, 19 in.Hg) is applied.

      3. Leave it for 1 minute and check that the vacuum pump needle does not move. If the result is not as specified, replace the intake manifold.

  2. INSPECT VACUUM SWITCHING VALVE


    1. Measure the resistance according to the value(s) in the table below.

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 33 to 39 Ω

      1 - Body ground

      2 - Body ground

      20°C (68°F) 10 kΩ or higher

      If the result is not as specified, replace the intake manifold.

    2. A01XEEIE10
      Text in Illustration
      *a Port E
      *b Filter
      B001CHY Airflow

      Check the operation according to the value(s) in the table below.


      1. Check that air flows from port E to the filter. If the result is not as specified, replace the intake manifold.

      2. A01XM06E10
        Text in Illustration
        *a Port E
        *b Port F
        B001CHY Airflow

        Apply battery voltage across the terminals.

      3. Check that air flows from port E to port F. If the result is not as specified, replace the intake manifold.