UREA PUMP CONTROL ECU REMOVAL

PROCEDURE


  1. REMOVE NO. 2 UREA PUMP CONTROL BRACKET


    1. A01XJJY

      Remove the 3 bolts and No. 2 urea pump control bracket from the frame LH.

  2. REMOVE NO. 3 UREA PUMP CONTROL BRACKET


    1. A01XE7K

      Remove the bolt and No. 3 urea pump control bracket from the No. 4 urea pump control bracket.

  3. REMOVE UREA PUMP CONTROL ECU


    1. A01XEWU

      Raise the lever while pushing the lock on the lever and disconnect the connector from the urea pump control ECU.

      Note

      After disconnecting a connector, make sure that dirt, water and other foreign matter does not contact the connector.

    2. A01XGD4

      Detach the 3 clamps and disconnect wire harness from the No. 4 urea pump control bracket and No. 1 urea pump control bracket.

    3. A01XKUF

      Remove the 3 bolts and No. 4 urea pump control bracket from the urea pump control ECU.

    4. A01XLOC

      Remove the 3 bolts and No. 1 urea pump control bracket from the frame LH.

    5. A01XKRR

      Remove the 3 bolts and urea pump control ECU from the No. 1 urea pump control bracket.