PROCEDURE
INSTALL UREA INJECTOR SET
Clean the surfaces of the urea injector set and front exhaust pipe assembly.
Install a new gasket and the urea injector set to the front exhaust pipe assembly with 2 new nuts.
Connect the connector to the urea injector set.
CONNECT UREA TUBE WITH HEATER ASSEMBLY
Note
Check for dirt or mud on the urea injector set and around the urea tube with heater connector before connection. Clean if necessary.
In order to prevent the urea injector set interior set portion from drying, perform installation and removal work as quickly as possible.
Connect the urea tube with heater assembly to the urea injector set.
Tech Tips
If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea injector set, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tube with heater connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea injector set with water to remove all solidified urea solution (white solids).
| *a | Retainer |
|
Push |
|
Push Down |
Align the axis of the connector with the axis of the urea injector set. Push the urea tube with heater connector into the urea injector set until the urea tube with heater connector makes a "click" sound.
Push down the retainer.
After connecting the urea injector set and the urea tube with heater connector, check that the urea injector set and urea tube with heater connector are securely connected by trying to pull them apart.