FUEL SEDIMENTER WARNING SWITCH INSPECTION

PROCEDURE


  1. INSPECT LEVEL WARNING SWITCH


    1. A01XMPPE01
      *1 On
      *2 Off

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 On Below 0.5 Ω
      1 - 2 Off 1 MΩ or higher

      If the result is not as specified, replace the level warning switch.