CAUTION / NOTICE / HINT
Note
When replacing the injectors (including shuffling the injectors between the cylinders), common rail or cylinder head, it is necessary to replace the injection pipes with new ones.
When replacing the fuel supply pump, common rail, cylinder block, cylinder head, cylinder head gasket or timing gear case, it is necessary to replace the fuel inlet pipe with a new one.
After removing the injection pipes and fuel inlet pipe, clean them with a brush and compressed air.
PROCEDURE
INSTALL SUCTION CONTROL VALVE ASSEMBLY
Note
Before replacing the suction control valve, be sure to clean the surrounding area.
When replacing the suction control valve, make sure that your hands are clean and do not use gloves, etc.
Apply engine oil to a new O-ring.
Note
Be sure to use clean engine oil.
Install the O-ring to the O-ring groove of the fuel supply pump.
Note
Make sure that the O-ring and O-ring groove are free of foreign matter and are not damaged.
| *1 | Guide Pin |
Install guide pins used for the insertion of the suction control valve to the bolt holes.
Tech Tips
When installing the guide pins, it is sufficient to fix them lightly in place by hand.
The guide pins are used to make sure that the suction control valve remains perpendicular to the fuel supply pump when it is inserted.
Apply engine oil to the O-ring at the end of the suction control valve.
Note
Be sure to use clean engine oil.
| *1 | Guide Pin |
| *2 | Fuel Supply Pump |
While making sure that the suction control valve and fuel supply pump remain perpendicular to each other, slide the suction control valve along the guide pins and insert it into the fuel supply pump as shown in the illustration.
Note
Make sure that the contact surfaces of the fuel supply pump and suction control valve are free of foreign matter and are not damaged.
Do not insert the suction control valve at an angle.
Make sure that the O-ring does not get pinched between the parts. If it does, replace it with a new one.
Insert the suction control valve until it contacts the fuel supply pump.
While holding the suction control valve in place, remove the guide pins, temporarily install 2 new bolts and uniformly tighten them by hand.
Note
Do not use tools. Tighten the bolts by hand until the surfaces of the suction control valve and fuel supply pump contact each other.
Using a 5 mm hexagon wrench, uniformly tighten the 2 bolts.
Connect the connector to the suction control valve.
Note
Make sure that there is not excessive slack or tension in the wire harness of the suction control valve.
INSTALL FUEL SUPPLY PUMP ASSEMBLY
ADD ENGINE COOLANT
BLEED AIR FROM FUEL SYSTEM
PERFORM FUEL SUPPLY PUMP INITIALIZATION
INSPECT FOR COOLANT LEAK
INSPECT FOR FUEL LEAK