RELAY ON-VEHICLE INSPECTION


  1. INSPECT HORN RELAY


    1. A01I2BLE01

      Remove the horn relay.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the horn relay.