UPPER CONSOLE PANEL SUB-ASSEMBLY
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| I179-1 (ACC) - I179-5 (PGND) | GR - W-B | Power source (ACC) | Power switch on (ACC) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| I179-2 (ACC) - I179-4 (GND1) | GR - W-B | Power source (ACC) | Power switch on (ACC) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| I179-3 (ILL+) - Body ground | G - Body ground | Illumination signal | Light control switch in off position | Below 1 V |
| Power switch off, light control switch in tail or head position | 11 to 14 V | |||
| I179-4 (GND1) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| I179-5 (PGND) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| I179-8 (ILL-) - Body ground | SB - Body ground | Illumination (rheostat) signal | Light control switch off | Below 1 V |
| Light control switch in tail or head position | Pulse generation | |||
| I179-9 (TAIL) - I179-5 (PGND) | G - W-B | Illumination signal | Light control switch off | Below 1 V |
| Power switch off, light control switch in tail or head position | 11 to 14 V | |||
| I179-10 (DIS) - Body ground | L - Body ground | Smart key system status signal | For 1500 ms after turning power switch from off to on (IG)*1 | 4.4 to 6.5 V |
| Being charged | Below 1 V | |||
| Charging suspended due to smart key system status*2 | 4.4 to 6.5 V |
*1: The upper console panel sub-assembly checks the status signal for 1500 ms when the power switch is turned from off to on (IG). If a status signal voltage of less than 1 V continues for 400 ms or more during the check, the upper console panel sub-assembly judges that the status signal is interrupted, blinks the indicators and stops the operation until the power switch is turned off then on (IG) again.
*2: For the status of the smart key system when charging is stopped temporarily, refer to System Description Click here.