REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)
Turn the power switch on (READY).
Check that A/C switch indicator is turned on when the following conditions are met.
| Item | Condition |
|---|---|
| A/C Switch | On |
| A/C operation time | 15 minutes or more |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Engine coolant temperature | 45°C (113°F) or more |
*: If the ambient temperature is not within the range shown, do not perform this check.
Tech Tips
The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.
Connect the Techstream to the DLC3.
Check for DTC B14B8.
| Result | Amount of Refrigerant | Corrective Action |
|---|---|---|
| DTC B14B8 is output | Empty or nearly empty | Check for refrigerant leaks using a halogen leak detector, and repair if necessary Click here. |
| DTC B14B8 is not output | Correct or insufficient | Perform a refrigerant shortage check using the Techstream. |
REFRIGERANT SHORTAGE CHECK USING THE TECHSTREAM
Connect the Techstream to the DLC3.
Turn the power switch on (READY).
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Shortage Check.
According to the display on the Techstream, perform the refrigerant shortage check when the following conditions are met.
| Item | Condition |
|---|---|
| A/C Switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| R/F Switch | Recirculation (Ambient temperature is 31°C (87°F) or less) |
| Fresh (Ambient temperature is 30°C (86°F) or more) | |
| Blower Speed | HI |
| Temperature Setting | MAX HOT |
*: If the ambient temperature is not within the range shown, do not perform this check.
Tech Tips
Refer to the Techstream operator's manual for further details.
A message indicating a refrigerant shortage is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
DTCs are not stored when performing the refrigerant shortage check using the Techstream.
| Result | Amount of Refrigerant | Corrective Action |
|---|---|---|
| Refrigerant shortage | Insufficient or leakage |
|
| Refrigerant correct | Correct | - |