METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.

WIRING DIAGRAM

A01I2Y6E46

INSPECTION PROCEDURE

Note

Inspect the fuses of circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)


    1. A01I61SE44
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Disconnect the I18 combination meter assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I18-20 (ES) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      I18-13 (IG+) - Body ground Power switch off Below 1 V
      Power switch on (IG) 11 to 14 V
      I18-1 (B) - Body ground Power switch off 11 to 14 V

    NG
    OK