LIN COMMUNICATION SYSTEM, Diagnostic DTC:B1206

DTC Code DTC Name
B1206 P/W Master Switch Communication Stop

DESCRIPTION

This DTC is stored when LIN communication between the multiplex network master switch assembly and main body ECU (multiplex network body ECU) stops for 10 seconds or more.

DTC No. DTC Detection Condition Trouble Area
B1206 No communication between multiplex network master switch assembly and main body ECU (multiplex network body ECU) for 10 seconds or more.
  • Multiplex network master switch assembly

  • Main body ECU (multiplex network body ECU)

  • Instrument panel junction block assembly

  • Wire harness or connector

  • ECU-B NO. 2 fuse

WIRING DIAGRAM

A01I3NJE37

INSPECTION PROCEDURE

Note


  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

  • When using the Techstream to troubleshoot with the power switch off:

    Connect the Techstream to the DLC3, and turn the courtesy switch on and off at 1.5-second intervals until communication between the Techstream and vehicle begins.

PROCEDURE


  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. Remove the instrument panel junction block assembly Click here.

      A01I5WKE01
    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

    3. Measure the resistance according to the value(s) in the table below.

      Tech Tips

      This inspection is to check the LIN line in the instrument panel junction block assembly that connects the wire harness to the built-in main body ECU (multiplex network body ECU).

      Standard Resistance
      Tester Connection Condition Specified Condition
      3B-30 (LIN2) - MB-16 (LIN2) Always Below 1 Ω
      Text in Illustration
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      *b

      Component without harness connected

      (Instrument Panel Junction Block Assembly)


    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY)


    1. Disconnect the K11 multiplex network master switch assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3B-30 (LIN2) - K11-6 (LIN1) Always Below 1 Ω
      3B-30 (LIN2) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY - AUXILIARY BATTERY, BODY GROUND)


    1. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      K11-3 (B) - K11-1 (GND) Power switch off 11 to 14 V
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      K11-1 (GND) - Body ground Always Below 1 Ω

    NG
    OK
  4. REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY


    1. Replace the multiplex network master switch assembly Click here.


    NEXT
  5. CHECK DTC OUTPUT


    1. Clear the DTC Click here.

    2. Recheck for DTCs.

      OK
      DTC B1206 is not output.

    NG
    OK