HYBRID CONTROL SYSTEM Inverter Low-voltage Circuit

DESCRIPTION

The cause of the malfunction may be the low-voltage circuit.

Check whether there is an open circuit in the inverter +B low-voltage power source system or a problem in the communication between the power management control ECU and inverter.

Related Parts Check
Area Inspection Step
Inverter +B low-voltage power source system check Check for inverter overcurrent malfunction. 1, 2
Communication malfunction between power management control ECU and MG-ECU inside inverter with converter assembly Check for inverter overcurrent malfunction due to communication malfunction. 3, 4
Check for short to ground in inverter +B low-voltage power source system - 5, 6, 7

WIRING DIAGRAM

A01I67VE14

INSPECTION PROCEDURE

This step is referenced from the procedures for each DTC.

If the inspection results below are normal, perform the next procedure for the referenced DTC.

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK FUSE (INV)


    1. A01I67BE01
      Text in Illustration
      *1 No. 2 Engine Room Relay Block
      *2 INV fuse

      Remove the INV fuse from the No. 2 engine room relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      INV fuse terminal Always Below 1Ω
    3. Install the INV fuse.


    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01I5YK

      Disconnect the A14 inverter with converter assembly connector.

    3. A01I645E06
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-10 (GND1) - Body ground Power switch off Below 1 Ω
      A14-11 (GND2) - Body ground Power switch off Below 1 Ω
    4. Connect the cable to the negative (-) auxiliary battery terminal.

    5. Turn the power switch on (IG).

    6. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A14-30 (+B) - Body ground Power switch on (IG) Same as auxiliary battery voltage
      A14-31 (+B2) - Body ground Power switch on (IG) Same as auxiliary battery voltage

      Note

      Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Turn the power switch off.

    8. Disconnect the cable from the negative (-) auxiliary battery terminal.

    9. Reconnect the A14 inverter with converter assembly connector.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38 power management control ECU connector.

    3. Disconnect the A14 inverter with converter assembly connector.

    4. A01I5W7E05
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A38-34 (HTM+) - A14-9 (HTM+) Power switch off Below 1 Ω
      A38-33 (HTM-) - A14-20 (HTM-) Power switch off Below 1 Ω
      A38-21 (MTH+) - A14-8 (MTH+) Power switch off Below 1 Ω
      A38-20 (MTH-) - A14-19 (MTH-) Power switch off Below 1 Ω
      A38-32 (REQ+) - A14-26 (REQ+) Power switch off Below 1 Ω
      A38-31 (REQ-) - A14-37 (REQ-) Power switch off Below 1 Ω
      A38-29 (CLK+) - A14-7 (CLK+) Power switch off Below 1 Ω
      A38-28 (CLK-) - A14-18 (CLK-) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A38-34 (HTM+) or A14-9 (HTM+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-33 (HTM-) or A14-20 (HTM-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-21 (MTH+) or A14-8 (MTH+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-20 (MTH-) or A14-19 (MTH-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-32 (REQ+) or A14-26 (REQ+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-31 (REQ-) or A14-37 (REQ-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-29 (CLK+) or A14-7 (CLK+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-28 (CLK-) or A14-18 (CLK-) - Body ground and other terminals Power switch off 10 kΩ or higher
    5. Connect the cable to the negative (-) auxiliary battery terminal.

    6. Turn the power switch on (IG).

    7. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A38-34 (HTM+) or A14-9 (HTM+) - Body ground Power switch on (IG) Below 1 V
      A38-33 (HTM-) or A14-20 (HTM-) - Body ground Power switch on (IG) Below 1 V
      A38-21 (MTH+) or A14-8 (MTH+) - Body ground Power switch on (IG) Below 1 V
      A38-20 (MTH-) or A14-19 (MTH-) - Body ground Power switch on (IG) Below 1 V
      A38-32 (REQ+) or A14-26 (REQ+) - Body ground Power switch on (IG) Below 1 V
      A38-31 (REQ-) or A14-37 (REQ-) - Body ground Power switch on (IG) Below 1 V
      A38-29 (CLK+) or A14-7 (CLK+) - Body ground Power switch on (IG) Below 1 V
      A38-28 (CLK-) or A14-18 (CLK-) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    8. Turn the power switch off.

    9. Disconnect the cable from the negative (-) auxiliary battery terminal.

    10. Reconnect the A14 inverter with converter assembly connector.

    11. Reconnect the A38 power management control ECU connector.


    NG
    OK
  4. CHECK POWER MANAGEMENT CONTROL ECU


    1. Disconnect the A38 power management control ECU connector.

    2. A01I2XXE01
      Text in Illustration
      *a

      Component without harness connected

      (Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A38-34 (HTM+) - A38-33 (HTM-) Power switch off 80 to 170 Ω
      A38-21 (MTH+) - A38-20 (MTH-) Power switch off 80 to 170 Ω
      A38-32 (REQ+) - A38-31 (REQ-) Power switch off 80 to 170 Ω
      A38-29 (CLK+) - A38-28 (CLK-) Power switch off 80 to 170 Ω
    3. Reconnect the A38 power management control ECU connector.


    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - INV FUSE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A14 inverter with converter assembly connector.

    3. A01I645E07
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-30 (+B) - Body ground Power switch off 10 kΩ or higher
      A14-31 (+B2) - Body ground Power switch off 10 kΩ or higher
    4. Reconnect the A14 inverter with converter assembly connector.


    NG
    OK
  6. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT
  7. REPAIR OR REPLACE HARNESS OR CONNECTOR


    NEXT