DESCRIPTION
Refer to the description for DTC P0C73-776 Click here.
The inverter water pump assembly sends the inverter water pump speed (measured value) signal to the power management control ECU. If the inverter water pump speed (measured value) signal is not sent to the power management control ECU when the power switch is on (READY), this DTC is stored.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P314A | 828 | The inverter water pump speed signal is not sent to the power management control ECU when the power switch is turned on (READY). (1 trip detection logic) |
|
Tech Tips
A malfunction (open, short to +B or short to ground) in the speed signal line from the inverter water pump assembly to the power management control ECU is detected.
A malfunction in the inverter water pump assembly power source circuit is detected.
A malfunction in power management control ECU power source circuit is detected.
| DTC No. | Active Test |
|---|---|
| P314A-828 |
|
| DTC No. | Active Test |
|---|---|
| P314A-828 | Activate the (Inverter) Water Pump |
MONITOR DESCRIPTION
The power management control ECU monitors speed of the inverter water pump assembly. If there is an abnormality in speed, the power management control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
| Related DTCs | P314A (INF 828): Water pump malfunction |
| Required sensors / components | Inverter Water Pump Assembly |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
| TMC's intellectual property | - |
COMPONENT OPERATING RANGE
| Power management control ECU | DTC P314A (INF 828) is not detected |
CONFIRMATION DRIVING PATTERN
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (IG) and turn the Techstream on.
Turn the power switch on (READY) and wait for 2 minutes or more. [A]
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [B]
Read the current DTCs.
Tech Tips
If a current DTC is output, the system is malfunctioning.
If current DTCs are not output, perform the following steps to check for permanent DTCs.
Check that the permanent DTCs are cleared.
If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0C73-776 Click here.
INSPECTION PROCEDURE
Note
If DTC P0A78-284, 286, P0A7A-322, 324, P0A94-553 or 557 is output, replace the inverter with converter assembly after this inspection.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 2 minutes or more.
PROCEDURE
CLEAR DTC
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Turn the power switch off.
| NEXT |
|
PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE THE (INVERTER) WATER PUMP)
Note
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
Tech Tips
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the Activate the Water Pump Active Test.
Touch the inverter water pump assembly and check that it is operating (vibrating).
| OK |
|---|
| The inverter water pump is operating (vibrating). |
Turn the power switch off.
| NG |
|
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors Click here.
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
Check the connector connections and contact pressure of the relevant terminals for the inverter water pump assembly connector Click here.
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WATER PUMP ASSEMBLY)
Disconnect the A38 power management control ECU connector.
Disconnect the A50 inverter water pump assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
*b | Front view of wire harness connector (to Inverter Water Pump Assembly) |
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the A38 power management control ECU connector.
Reconnect the A50 inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
Disconnect the A50 inverter water pump assembly connector.
Turn the power switch on (IG).
| *a | Component with harness connected (Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Reconnect the A50 inverter water pump assembly connector.
| NG |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| OK |
|
CLEAR DTC
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Turn the power switch off.
| NEXT |
|
PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE THE (INVERTER) WATER PUMP)
Note
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
Tech Tips
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the "Activate the Water Pump" Active Test.
| *a | Component with harness connected (Power Management Control ECU) |
Connect an oscilloscope between the power management control ECU terminals specified in the table below, and measure the waveform.
| Item | Content |
|---|---|
| Terminal | A38-12 (NIWP) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 100 ms./DIV. |
| Condition | Power switch on (IG), during Active Test |
| OK |
|---|
| The duration of wavelength is 300 msec or less. |
Turn the power switch off.
| NG |
|
REPLACE INVERTER WATER PUMP ASSEMBLY Click here |
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
Check the connector connections and contact pressure of the relevant terminals for the inverter water pump assembly connector Click here.
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK INSTALLATION CONDITION (INV W/PMP RELAY)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Check installation condition of the INV W/PMP relay.
| OK |
|---|
| INV W/PMP relay is installed correctly. |
| NG |
|
INSPECT RELAY (INV W/PMP) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (IGCT RELAY - INV W/PMP RELAY)
Remove the IGCT relay and INV W/PMP relay from the No. 2 engine room relay block.
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
| *3 | IGCT Relay |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the holders will be damaged.
Install the IGCT relay and INV W/PMP relay.
| NG |
|
CHECK INSTALLATION CONDITION (INV W/PMP RLY FUSE) Click here |
| OK |
|
INSPECT RELAY (INV W/PMP)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Install the INV W/PMP relay.
| NG |
|
CHECK RELAY HOLDER TERMINAL (INV W/PMP RELAY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
Disconnect the A50 inverter water pump assembly connector.
| *a | Front view of wire harness connector (to Inverter Water Pump Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Reconnect the A50 inverter water pump assembly connector.
| NG |
|
CHECK INSTALLATION CONDITION (INV W/PMP FUSE) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
| *a | Front view of wire harness connector (to Inverter Water Pump Assembly) |
Disconnect the A50 inverter water pump assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the A50 inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE INVERTER WATER PUMP ASSEMBLY Click here
CHECK INSTALLATION CONDITION (INV W/PMP FUSE)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Fuse |
Check installation condition of the INV W/PMP fuse.
| OK |
|---|
| INV W/PMP fuse is installed correctly. |
| NG |
|
CONNECT SECURELY |
| OK |
|
INSPECT RELAY (INV W/PMP)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Install the INV W/PMP relay.
| NG |
|
CHECK RELAY HOLDER TERMINAL (INV W/PMP RELAY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - NO. 2 ENGINE ROOM RELAY BLOCK)
Remove the INV W/PMP relay from the No. 2 engine room relay block.
Disconnect the A50 inverter water pump assembly connector.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 2 Engine Room Relay Block | *2 | INV W/PMP Relay |
| *a | Front view of wire harness connector (to Inverter Water Pump Assembly) |
- | - |
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Install the INV W/PMP relay.
Connect the inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK FUSE (INV W/PMP)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Fuse |
Remove the INV W/PMP fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the INV W/PMP fuse.
| NG |
|
REPLACE INVERTER WATER PUMP ASSEMBLY Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP FUSE HOLDER TERMINAL OR INV W/PMP RELAY HOLDER TERMINAL)
REPLACE INVERTER WATER PUMP ASSEMBLY
| NEXT |
|
REPLACE FUSE (INV W/PMP)
CHECK RELAY HOLDER TERMINAL (INV W/PMP RELAY)
Check the terminals of the INV W/PMP relay holder.
| OK |
|---|
| The terminals of the INV W/PMP relay holder are not bent, loose or corroded. |
| NG |
|
CHECK FUSE (INV W/PMP RLY) Click here |
| OK |
|
CHECK FUSE (INV W/PMP RLY)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Remove the INV W/PMP RLY fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the INV W/PMP RLY fuse.
| NG |
|
REPLACE RELAY (INV W/PMP) Click here |
| OK |
|
REPLACE RELAY (INV W/PMP)
REPLACE RELAY (INV W/PMP)
| NEXT |
|
REPLACE FUSE (INV W/PMP RLY)
CHECK RELAY HOLDER TERMINAL (INV W/PMP RELAY)
Check the terminals of the INV W/PMP relay holder.
| OK |
|---|
| The terminals of the INV W/PMP relay holder are not bent, loose or corroded. |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RELAY HOLDER TERMINAL) Click here |
| OK |
|
REPLACE RELAY (INV W/PMP)
CHECK FUSE (INV W/PMP RLY)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Remove the INV W/PMP RLY fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the INV W/PMP RLY fuse.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RELAY HOLDER TERMINAL) Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RELAY HOLDER TERMINAL)
| NEXT |
|
REPLACE RELAY (INV W/PMP)
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RELAY HOLDER TERMINAL)
| NEXT |
|
REPLACE RELAY (INV W/PMP)
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RELAY HOLDER TERMINAL)
| NEXT |
|
REPLACE FUSE (INV W/PMP RLY)
| NEXT |
|
REPLACE RELAY (INV W/PMP)
CHECK INSTALLATION CONDITION (INV W/PMP RLY FUSE)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Check installation condition of the INV W/PMP RLY fuse.
| OK |
|---|
| INV W/PMP RLY fuse is installed correctly. |
| NG |
|
INSPECT RELAY (INV W/PMP) Click here |
| OK |
|
CHECK FUSE (INV W/PMP RLY)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Remove the INV W/PMP RLY fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the INV W/PMP RLY fuse.
| NG |
|
CHECK FUSE HOLDER TERMINAL (INV W/PMP RLY FUSE) Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RLY FUSE HOLDER TERMINAL)
CHECK FUSE HOLDER TERMINAL (INV W/PMP RLY FUSE)
Check the terminals of the INV W/PMP RLY fuse holder.
| OK |
|---|
| The terminals of the INV W/PMP RLY fuse holder are not bent, loose or corroded. |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RLY FUSE HOLDER TERMINAL) Click here |
| OK |
|
REPLACE FUSE (INV W/PMP RLY)
REPAIR OR REPLACE HARNESS OR CONNECTOR (INV W/PMP RLY FUSE HOLDER TERMINAL)
| NEXT |
|
REPLACE FUSE (INV W/PMP RLY)
INSPECT RELAY (INV W/PMP)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Install the INV W/PMP relay.
| NG |
|
REPLACE RELAY (INV W/PMP) Click here |
| OK |
|
CONNECT SECURELY (INV W/PMP RLY FUSE)
INSPECT RELAY (INV W/PMP)
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Install the INV W/PMP relay.
| NG |
|
REPLACE RELAY (INV W/PMP) Click here |
| OK |
|
CONNECT SECURELY (INV W/PMP RELAY)
REPLACE RELAY (INV W/PMP)
| NEXT |
|
CONNECT SECURELY (INV W/PMP RLY FUSE)
REPLACE RELAY (INV W/PMP)
| NEXT |
|
CONNECT SECURELY (INV W/PMP RELAY)