INVERTER WITH CONVERTER REMOVAL


  1. PRECAUTION

    Click here

  2. REMOVE SERVICE PLUG GRIP

    Click here

  3. DRAIN COOLANT (for Inverter)

    Note


    • Do not reuse the drained coolant because it may contain foreign objects.

    • Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.


    1. Remove the reserve tank cap.

      CAUTION:

      To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.

    2. A01I4EO

      Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.

      CAUTION:

      Use caution when handling coolant immediately after driving or in summer because it may be hot.

    3. Install the plug with a new gasket.

      Torque:
      39 N*m  { 397 kgf*cm, 29 ft.*lbf }
  4. REMOVE CONNECTOR COVER ASSEMBLY

    CAUTION:


    • Do not touch the high voltage connectors and terminals for 10 minutes after the service plug grip is removed.

    • Wear insulated gloves.

    Note

    Do not start the hybrid system with the service plug grip removed because it may cause a malfunction.


    1. A01I2Z5

      Remove the 2 bolts and connector cover assembly.

      Note


      • Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  5. CHECK TERMINAL VOLTAGE

    CAUTION:

    Wear insulated gloves.

    Note

    Do not allow any foreign matter or water to enter the inverter with converter assembly.


    1. A01I4LM

      Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

      Standard voltage
      0 V

      Tech Tips

      Use a measuring range of DC 750 V or more on the voltmeter.

  6. TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01I2N9

      Temporarily install the connector cover assembly with the bolt to prevent any foreign matter or water from entering the inverter with converter assembly.

  7. REMOVE COOL AIR INTAKE DUCT SEAL


    1. A01I34Z

      Remove the 9 clips and cool air intake duct seal.

  8. REMOVE INLET AIR CLEANER ASSEMBLY


    1. A01I41G

      Remove the 2 bolts and inlet air cleaner assembly.

  9. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    1. A01I34Q

      Disconnect the mass air flow meter connector and wire harness clamp from the air cleaner cap sub-assembly.

    2. Disconnect the ventilation hose from the cylinder head cover.

    3. Disconnect the connector and wire harness clamp.

    4. A01I2EB

      Release the 2 clamps and remove the air cleaner cap sub-assembly.

    5. A01I32VE01
      Text in Illustration
      *1 Retainer
      *2 Fuel Tube Connector
      *3 Pipe
      *4 O-ring
      *a Pinch
      *b Pull

      Disconnect the 2 fuel vapor feed hoses.

      Note


      • Remove any dirt or foreign matter on the fuel tube connector before performing this work.

      • Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the fuel tube connector has an O-ring that seals the pipe.

      • Perform this work by hand. Do not use any tools.

      • Protect the disconnected parts by covering them with plastic bags after disconnecting each fuel vapor feed hose.

    6. A01I3VF

      Loosen the hose clamp and disconnect the air cleaner hose from the throttle with motor body assembly.

  10. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  11. REMOVE AIR CLEANER CASE SUB-ASSEMBLY


    1. A01I575E03
      Text in Illustration
      *a Projection

      Remove the 2 bolts and air cleaner case sub-assembly.

  12. REMOVE NO. 5 INVERTER BRACKET


    1. A01I3ST

      Remove the 2 bolts and No. 5 inverter bracket.

  13. REMOVE NO. 4 INVERTER BRACKET


    1. A01I4TF

      Remove the 3 bolts and No. 4 inverter bracket.

  14. REMOVE UPPER INVERTER COVER

    CAUTION:

    Wear insulated gloves.


    1. A01I4GL

      Remove the 2 bolts and upper inverter cover (generator cable side).

      Note


      • Make sure to pull the upper inverter cover straight up, as a connector is connected to the bottom of the cover.

      • Do not touch the upper inverter cover waterproofing rubber.

  15. DISCONNECT GENERATOR CABLE

    CAUTION:

    Wear insulated gloves.


    1. A01I585

      Using an insulated tool, remove the 3 bolts.

    2. A01I2OU

      Disconnect the 2 wire harness clamps and separate the generator cable.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  16. REMOVE UPPER INVERTER COVER

    CAUTION:

    Wear insulated gloves.


    1. A01I61H

      Remove the 2 bolts and upper inverter cover (motor cable side).

      Note


      • Make sure to pull the upper inverter cover straight up, as a connector is connected to the bottom of the cover.

      • Do not touch the upper inverter cover waterproofing rubber.

  17. DISCONNECT MOTOR CABLE

    CAUTION:

    Wear insulated gloves.


    1. A01I5VP

      Using an insulated tool, remove the 3 bolts.

    2. A01I4JR

      Disconnect the 3 wire harness clamps and separate the motor cable.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  18. REMOVE NO. 3 MOTOR CABLE BRACKET


    1. A01I4LG

      Disconnect the hose clamp from the No. 3 motor cable bracket.

      Tech Tips

      Do not remove the hose clamp from the hose.

    2. Remove the 2 bolts and No. 3 motor cable bracket.

  19. REMOVE CONNECTOR COVER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01I5B0

      Remove the bolt and connector cover assembly.

      Note


      • Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  20. DISCONNECT NO. 4 ENGINE WIRE

    CAUTION:

    Wear insulated gloves.


    1. A01I2SJ

      Disconnect the No. 4 engine wire.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

    2. A01I4HP

      Disconnect the wire harness clamp.

  21. DISCONNECT NO. 4 FLOOR WIRE

    CAUTION:

    Wear insulated gloves.


    1. A01I563

      Remove the bolt.

    2. A01I2U5

      Disconnect the wire harness clamp and connector.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  22. TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01I2N9

      Temporarily install the connector cover assembly with the bolt to prevent any foreign matter or water from entering the inverter with converter assembly.

  23. DISCONNECT LOW VOLTAGE CONNECTOR

    Note


    • Insulate the removed terminals with insulating tape.

    • Do not allow any foreign matter or water to enter the inverter with converter assembly.


    1. A01I45E

      Raise the lock lever and disconnect the 3 low voltage connectors.

    2. Disconnect the low voltage connector from the inverter with converter assembly.

  24. DISCONNECT NO. 3 ENGINE ROOM WIRE


    1. Remove the relay block cover.

    2. A01I67C

      Remove the nut.

    3. Disconnect the wire harness clamp and No. 3 engine room wire.

  25. REMOVE NO. 4 INVERTER COOLING HOSE


    1. A01I5S0E01
      Text in Illustration
      *1 Retainer

      Release the retainer and disconnect the No. 4 inverter cooling hose from the inverter with converter assembly.

    2. A01I5HJ

      Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.

  26. REMOVE NO. 1 INVERTER COOLING HOSE ASSEMBLY


    1. A01I46JE01
      Text in Illustration
      *1 Retainer

      Release the retainer and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.

    2. A01I2E2

      Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.

  27. REMOVE INVERTER WITH CONVERTER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01I61YE01
      Text in Illustration
      *1 No. 3 Engine Room Wire
      *2 Hook

      Temporarily secure the No. 3 engine room wire with the inverter with converter assembly hook as shown in the illustration.

    2. A01I4RE

      Remove the 2 bolts, nut and inverter with converter assembly.

      Note


      • Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly. When removing the inverter with converter assembly, do not damage the parts around it.

      • To prevent damage, do not hold the inverter with converter assembly by the connectors.

      • To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

    3. A01I2TV

      Even after the coolant is drained, coolant remains in the inverter with converter assembly due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter to prevent coolant from spilling out or foreign matter from entering the inverter with converter.

  28. REMOVE HIGH VOLTAGE FUSE

    CAUTION:

    Wear insulated gloves.

    Tech Tips

    Perform this procedure only when replacement of the high voltage fuse is necessary.


    1. A01I40H

      Remove the bolt and connector cover assembly.

      Note


      • Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

    2. A01I2T4

      Remove the 2 nuts and high voltage fuse.

    3. A01I40H

      Temporarily install the connector cover assembly with the bolt to prevent any foreign matter or water from entering the inverter with converter assembly.

  29. REMOVE AIR CLEANER BRACKET


    1. A01I3DT

      Remove the bolt and air cleaner bracket.

  30. REMOVE AIR CLEANER BRACKET


    1. A01I387

      Remove the bolt and air cleaner bracket.

  31. REMOVE NO. 1 INVERTER BRACKET


    1. A01I3MI

      Remove the 2 bolts and No. 1 inverter bracket.

  32. REMOVE NO. 2 INVERTER BRACKET


    1. A01I618

      Remove the 2 bolts and No. 2 inverter bracket.

  33. REMOVE NO. 3 INVERTER BRACKET


    1. A01I4DM

      Remove the 2 bolts and No. 3 inverter bracket.

  34. REMOVE NO. 1 MOTOR CABLE BRACKET


    1. A01I30D

      Remove the 2 bolts and No. 1 motor cable bracket.

  35. REMOVE NO. 2 MOTOR CABLE BRACKET


    1. A01I4G9

      Remove the 2 bolts and No. 2 motor cable bracket.

  36. REMOVE NO. 1 INVERTER COOLING HOSE


    1. A01I5MDE01
      Text in Illustration
      *1 Retainer

      Release the retainer and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.

    2. Remove the No. 1 inverter cooling hose.

    3. A01I5HJ

      Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.

  37. REMOVE NO. 3 ENGINE ROOM WIRE


    1. A01I2LU

      Open the cover.

      Note

      Do not twist the cover excessively when opening it.

    2. Remove the nut and No. 3 engine room wire.