DTC SUMMARY
MALFUNCTION DESCRIPTIONThis DTC indicates when the temperature of the inverter for the motor has become abnormal. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description | Step |
|---|---|---|
| Inverter low-voltage circuit | The connectors are not connected properly | 3 |
| Hybrid cooling system | Coolant is leaking, insufficient coolant level, frozen or the passenger of coolant is clogged. | 4 |
| Resolver | Open or short circuit in the motor resolver or generator resolver | 5, 6 |
| Motor or generator |
|
7, 8 |
| Inverter |
|
9 |
DESCRIPTION
For a description of the inverter Click here.
If the motor inverter overheats, has a circuit malfunction, or has an internal short, the inverter transmits this information to the MG ECU via the motor inverter fail signal line.
Tech Tips
The term "drive motor A" indicates motor (MG2).
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A78 | 284 | Motor inverter fail signal detected (overheat): Motor inverter temperature is excessively high. (1 trip detection logic) |
|
| DTC No. | Data List |
|---|---|
| P0A78-284 |
|
MONITOR DESCRIPTION
If the motor inverter overheats, it will transmit an inverter fail signal to the MG ECU. Upon receiving this signal, the power management control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
| Related DTCs | P0A78 (INF 284): MFIV detection (Over heat malfunction) |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
| TMC's intellectual property | - |
COMPONENT OPERATING RANGE
| Power management control ECU | DTC P0A78 (INF 284) is not detected |
CONFIRMATION DRIVING PATTERN
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (IG) and turn the Techstream on.
Turn the power switch on (READY).
With the shift lever in P, wait 5 seconds. [A]
Tech Tips
Check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc).
Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 10 minutes. [B]
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
Read the current DTCs.
Tech Tips
If a current DTC is output, the system is malfunctioning.
If a current DTC is not output and want to confirm permanent DTC, perform the following procedure.
Check that permanent DTCs are cleared.
If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0A1A-200 Click here.
Refer to the wiring diagram for DTC P0AA6-526 Click here.
Refer to the wiring diagram for DTC P324E-788 Click here.
Refer to the wiring diagram for DTC U0110-159 Click here.
Refer to the wiring diagram for the inverter low-voltage circuit Click here.
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
After troubleshooting and repairing all output DTCs, be sure to replace the inverter with converter assembly. (Because the inverter with converter assembly may have been broken or damaged due to overheating.)
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 5 seconds or more.
Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 10 minutes.
During the road test, check the data list item "Inverter Temp-(MG2)" to prevent the motor inverter from overheating.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Note
If P0A78-202 is output, troubleshoot it first. After completing the troubleshooting for P0A78-202, return to perform troubleshooting for this DTC.
Parts repaired or replaced during troubleshooting for P0A78-202 do not need to be re-inspected in this diagnosis procedure.
Turn the power switch off.
| B |
|
GO TO DTC CHART (P0A78-202) Click here |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
Tech Tips
If P0A78-202 was not output in step 1 of this diagnosis procedure, check Table 1 below.
If P0A78-202 was output in step 1 of this diagnosis procedure, repair that DTC first, then check Table 2 below.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B-168, 192, 193, 198, 661, 786, 794, 795, 796 | Drive Motor "A" Control Module | |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module | |
| Power source circuit malfunction | P0A1B-163, 164, 511, 512 | Drive Motor "A" Control Module |
| Sensor and actuator circuit malfunction | P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance | |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low | |
| P0A4B-253 | Generator Position Sensor Circuit | |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance | |
| P0A4D-255 | Generator Position Sensor Circuit Low | |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current | |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current | |
| P0A72 (all INF codes)*1 | Generator Phase V Current | |
| P0A75 (all INF codes)*1 | Generator Phase W Current | |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance | |
| P314A-828 | Inverter Coolant Pump Speed Signal | |
| System malfunction | P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance | |
| P0A90-509 | Drive Motor "A" Performance | |
| P0A92-521 | Hybrid Generator Performance | |
| P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC / DC Converter Performance | |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long | |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B-168, 192, 193, 198, 661, 786, 794, 795, 796 | Drive Motor "A" Control Module | |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module | |
| Power source circuit malfunction | P0A1B-163, 164, 511, 512 | Drive Motor "A" Control Module |
| Sensor and actuator circuit malfunction | P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance | |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low | |
| P0A4B-253 | Generator Position Sensor Circuit | |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance | |
| P0A4D-255 | Generator Position Sensor Circuit Low | |
| P0A60-294 | Drive Motor "A" Phase V Current | |
| P0A63-302 | Drive Motor "A" Phase W Current | |
| P0A72 (all INF codes)*1 | Generator Phase V Current | |
| P0A75 (all INF codes)*1 | Generator Phase W Current | |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance | |
| P314A-828 | Inverter Coolant Pump Speed Signal | |
| System malfunction | P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance | |
| P0A92-521 | Hybrid Generator Performance | |
| P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC / DC Converter Performance | |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long | |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A78-284 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK COOLING SYSTEM
| NEXT |
|
CHECK GENERATOR RESOLVER CIRCUIT
| NEXT |
|
CHECK MOTOR RESOLVER CIRCUIT
| NEXT |
|
CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
| NEXT |
|
CHECK MOTOR HIGH-VOLTAGE CIRCUIT
| NEXT |
|
CHECK INVERTER LOW-VOLTAGE CIRCUIT
Tech Tips
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
| NEXT |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here