DATA LIST
Note
Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Hybrid Control / Data List.
Check the results by referring to the following table.
Tech Tips
When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.
Using a custom list makes it possible to easily select smaller groups of related Data List items.
The following custom lists are available:
Primary
HV Battery
Electric Leakage
Boost/Lower Converter
High Voltage Charge
HV Transmission
Auxiliary Battery
Thermo Sensor
Drive Performance
Elec Shift Lever System
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Engine Coolant Temp | Engine coolant temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Cold start → Fully warmed up: Gradually rises After warming up: 75 to 100°C (167 to 212°F) |
- |
| Engine Revolution | Engine speed/ Min.: 0 rpm, Max.: 16383 rpm |
While idling after the engine is warmed up and inspection mode: Approximately 900 rpm While driving at a constant speed: No significant fluctuation |
- |
| Vehicle Spd | Vehicle speed/ Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
Vehicle stopped: 0 km/h (0 mph) While driving at a constant speed: No significant fluctuation |
- |
| Engine Run Time | Elapsed time after starting engine/ Min.: 0 s, Max.: 65535 s |
Elapsed time after starting engine | Elapsed time from initial engine start until the power switch is turned off. |
| +B | Auxiliary battery voltage (+B1,+B2 terminal) When power switch on (READY): approx. 13.8 to 14.7 V. When power switch on (IG): same as auxiliary battery voltage (approx. 12 V). If the voltage becomes 11 V or less when the power switch is on (READY), the power management control ECU stores inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the power switch will not be able to be turned on (READY). Min.: 0.00 V, Max.: 65.53 V |
Constant: 11.00 to 15.00 V |
|
| Accel Pedal Pos #1 | Accelerator pedal position sensor No.1 (Sensor voltage is multiplied by 20 and displayed as a percentage) Min.: 0.0%, Max.: 100.0% |
Accelerator pedal depressed: Changes with accelerator pedal pressure |
Accelerator pedal sensor assembly |
| Accel Pedal Pos #2 | Accelerator pedal position sensor No.2 (Sensor voltage is multiplied by 20 and displayed as a percentage) Min.: 0.0%, Max.: 100.0% |
Accelerator pedal depressed: Changes with accelerator pedal pressure |
Accelerator pedal sensor assembly |
| Ambient Temperature | Ambient air temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Power switch on (IG): Same as ambient air temperature |
Ambient temperature sensor |
| Intake Air Temperature | Engine intake air temperature/ Min.: -40°C (-40°F), Max.: 140°C (284°F) |
Constant: Same as ambient air temperature |
- |
| DTC Clear Warm Up | The number of times the engine is warmed up after clearing DTCs/ Min.: 0, Max.: 255 |
MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine: Increases once |
- |
| DTC Clear Run Distance | Drive distance after clearing DTCs/ Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
- | - |
| DTC Clear Min | Elapsed time after clearing DTCs/ Min.: 0 min, Max.: 65535 min |
- | Time elapsed after DTCs are cleared (Not counted when the power switch is off) |
| MIL on Engine Run Time | Driving time after a malfunction occurs/ Min.: 0 min, Max.: 65535 min |
- | - |
| MIL Status | MIL status/ ON or OFF |
MIL ON: ON | Constant ON: Repair in accordance with detected DTCs |
| MIL on Run Distance | Travel distance after a malfunction occurs/ Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
- | - |
| Model Code | Model code | AVV5# | - |
| Engine Code | Engine code | P314 | - |
| ECU Code | ECU code | - | - |
| Destination | Destination | A | - |
| OBD Requirements | OBD requirements | OBD2 | - |
| MAP | Intake manifold pressure/ Min.: 0 kPa, Max.: 255 kPa |
Power switch on (IG) or engine stopped: Atmosphere pressure |
Valued less than atmospheric pressure are indicated while the engine is running |
| Atmosphere Pressure | Atmospheric pressure/ Min.: 0 kPa, Max.: 255 kPa |
Constant: Atmosphere pressure |
- |
| Number of Emission DTC | The number of emission DTCs | - | - |
| Ready Signal | State of system (READY)/ ON or OFF |
Power switch on (READY): ON |
- |
| Motor(MG2) Revolution | Motor (MG2) revolution speed (detected by resolver sensor) Motor (MG2) revolution speed changes in proportion to vehicle speed. Motor (MG2) revolution speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) revolution speed. Min.: -32768 rpm, Max.: 32767 rpm |
While driving: Varies depending on vehicle speed |
|
| Motor(MG2) Torq | Motor (MG2) torque request value/ Min.: -4096.00 Nm, Max.: 4095.87 Nm |
While driving: Varies depending on vehicle operating conditions |
|
| M(MG2) Trq Exec Val | Motor (MG2) torque execution value/ Min.: -4096.00 Nm, Max.: 4095.87 Nm |
After full-load acceleration with power switch on (READY) and engine stopped: Less than +/-20% of motor (MG2) torque |
|
| Generator(MG1) Rev | Generator (MG1) revolution speed (detected by resolver sensor) Generator (MG1) revolution speed is set to obtain requested target engine speed Min.: -32768 rpm, Max.: 32767 rpm |
During charge or discharge: Varies depending on vehicle operating conditions |
|
| Generator(MG1) Torq | Generator (MG1) torque request value/ Min.: -4096.00 Nm, Max.: 4095.87 Nm |
During charge or discharge: Varies depending on vehicle operating conditions |
|
| G(MG1) Trq Exec Val | Generator (MG1) torque execution value/ Min.: -4096.00 Nm, Max.: 4095.87 Nm |
One second after engine automatically starts with shift lever in P (Condition before engine start: Power switch on (READY), engine stopped, A/C fan speed high and headlights on): Less than +/- 20% of generator (MG1) torque |
|
| Regenerative Brake Torq | Motor (MG2) regenerative braking execution torque/ Min.: -4096.0 Nm, Max.: 4095.0 Nm |
While braking: Varies depending on vehicle operation conditions |
|
| Rqst Regen Brake Torq | Requested motor (MG2) regenerative braking torque/ Min.: -4096.0 Nm, Max.: 4095.0 Nm |
While braking: Varies depending on vehicle operation conditions |
|
| Inverter Temp-(MG1) | Generator inverter temperature/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Inverter Temp-(MG2) | Motor inverter temperature/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Motor Temp No2 | Generator (MG1) temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
GMT terminal |
| Motor Temp No1 | Motor (MG2) temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
MMT terminal |
| Accelerator Degree | Accelerator pedal depressed angle/ Min.: 0.0%, Max.: 100.0% |
Accelerator pedal depressed: Changes with accelerator pedal pressure |
Accelerator pedal sensor assembly |
| Request Power | Requested engine power by power management control ECU to ECM/ Min.: 0 W, Max.: 655350 W |
While driving with the engine running: Varies depending on vehicle operating conditions |
|
| Target Engine Rev | Target engine speed requested by power management control ECU to ECM/ Min.: 0 rpm, Max.: 65535 rpm |
While driving with the engine running: Varies depending on vehicle operating conditions |
|
| Engine Rev (Sensor) | Engine speed/ Min.: 0 rpm, Max.: 16383 rpm |
While idling after the engine is warmed up: Approximately 1000 rpm While driving at a constant speed: No significant fluctuation |
- |
| Total Distance Traveled | Drive total distance/ Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) |
- | - |
| State of Charge (All Bat) | HV battery state of charge Primary calculated from charging and discharging amperage Min.: 0.0%, Max.: 100.0% |
Constant: 0.0 to 100.0% |
|
| Master Cylinder Ctrl Trq | Braking torque equivalent to master cylinder brake fluid pressure/ Min.: -4096.0 Nm, Max.: 4095.0 Nm |
Brake pedal depressed: Changes with the brake pedal pressure |
Master cylinder pressure sensor |
| Power Resource VB | HV battery voltage/ Min.: 0.0 V, Max.: 6553.5 V |
Power switch on (READY): 204.0 to 340.0 V |
|
| Power Resource IB | HV battery current/ Min.: -327.68 A, Max.: 327.67 A |
Power switch on (READY): -200.00 to 200.00 A |
|
| VL-Voltage before Boosting | High voltage before it is boosted/ Min.: 0 V, Max.: 450 V |
Power switch on (READY): Practically the same as the HV battery voltage |
|
| VH-Voltage after Boosting | High voltage after it is boosted/ Min.: 0 V, Max.: 1000 V |
Engine revving up with shift lever in P: After boosted voltage to below 650 V |
Inverter with converter assembly |
| Boost Ratio | Boost converter boost ratio/ Min.: 0.0%, Max.: 100.0% |
- | Inverter with converter assembly |
| Drive Condition ID | Drive condition ID |
|
|
| Shift Sensor Shift Pos | Shift position/ P/R/N/D/B |
Matches currently selected shift position: P, R, N, D or B |
Shift lever position sensor |
| Crank Position | Crankshaft position/ Min.: -128 °CA, Max.: 127 °CA |
- | - |
| A/C Consumption Pwr | A/C consumption power/ Min.: 0 W, Max.: 12750 W |
While the air conditioning system is operating: 0 to 5000 W | Air conditioning system |
| Short Wave Highest Val | Waveform voltage in leak detection circuit in battery smart unit/ Min.: 0.00 V, Max.: 4.98 V |
- | High voltage circuit |
| MG1 Control Mode | Generator (MG1) control mode/ Min.: 0, Max.: 2 |
PWM: 0 Variable PWM: 1 Rectangular wave: 2 |
- |
| MG1 Carrier Frequency | Generator (MG1) carrier frequency/ 0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz/10.00kHz |
- | - |
| MG2 Control Mode | Motor (MG2) control mode/ Min.: 0, Max.: 2 |
PWM: 0 Variable PWM: 1 Rectangular wave: 2 |
- |
| MG2 Carrier Frequency | Motor (MG2) carrier frequency/ 0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz |
- | - |
| Num of Current Code | The number of current DTCs/ Min.: 0, Max.: 255 |
- | - |
| Num of History Code | The number of history DTCs/ Min.: 0, Max.: 255 |
- | - |
| Check Mode | Check Mode/ ON or OFF |
- | - |
| Shift Sensor SW - P | Shift lever position sensor/ ON or OFF |
Shift lever in P: ON Shift lever in any position other than P: OFF |
Shift lever position sensor |
| Shift Sensor SW - R | Shift lever position sensor/ ON or OFF |
Shift lever in R: ON Shift lever in any position other than R: OFF |
Shift lever position sensor |
| Shift Sensor SW - N | Shift lever position sensor/ ON or OFF |
Shift lever in N: ON Shift lever in any position other than N: OFF |
Shift lever position sensor |
| Shift Sensor SW - D | Shift lever position sensor/ ON or OFF |
Shift lever in D: ON Shift lever in any position other than D: OFF |
Shift lever position sensor |
| Shift Sensor SW - B | Shift lever position sensor/ ON or OFF |
Shift lever in B: ON Shift lever in any position other than B: OFF |
Shift lever position sensor |
| Shift Sensor SW - FD | Shift lever position sensor/ ON or OFF |
Shift lever in D or B: ON Shift lever in any position other than D or B: OFF |
Shift lever position sensor |
| Shift Sensor SW - RV | Shift lever position sensor/ ON or OFF |
Shift lever in R: ON Shift lever in any position other than R: OFF |
Shift lever position sensor |
| Shift Sensor SW - MJ | Shift lever position sensor/ ON or OFF |
Shift lever in P, R, N, D or B: ON Shift lever in any position other than P, R, N, D or B: OFF |
Shift lever position sensor |
| Calculate Load | Engine load (value increases in proportion to increase in load)/ Min.: 0.0%, Max.: 100.0% |
Engine idling with warm engine, air conditioner off, shift lever in P and inspection mode selected: 20.0 to 40.0% Engine speed of 2500 rpm, air conditioner off, shift lever in P and inspection mode selected: 15.0 to 35.0% |
|
| Throttle Position | Throttle position sensor/ Min.: 0.0%, Max.: 100.0% |
Throttle valve fully closed: 10.0 to 24.0% |
Throttle valve status |
| DCDC Cnv Tar Pulse Duty | Target auxiliary battery voltage/ Min.: 0.0%, Max.: 399.9% |
- | - |
| Inverter Coolant Water Temperature | Inverter coolant temperature/ Min.: -40°C (-40°F), Max.: 110°C (230°F) |
Cold start → Fully warmed up: Gradually rises System operating normally: Controlled at 65°C (149°F) or less |
|
| Cooling Fan 0 | Battery cooling blower assembly operation request/ Min.: 0.0%, Max.: 100.0% |
- | - |
| Inverter W/P Revolution | Inverter water pump assembly speed/ Min.: 0 rpm, Max.: 15000 rpm |
Power switch on (READY): 1625 to 5875 rpm When the inverter water pump assembly is not operating: Lower than 625 rpm |
|
| Prohibit DC/DC conv sig | DC/DC converter prohibition signal/ ON or OFF |
Power switch on (IG): ON (Prohibited) Power switch on (READY): OFF (Permitted) |
|
| EV Request | EV mode transition availability/ ON or OFF |
In EV mode: ON |
- |
| TRC OFF Switch | VSC condition/ OFF/TRC/TRC, VSC |
VSC OFF switch on: OFF |
- |
| Starter Switch | Starter ON / OFF signal/ ON or OFF |
Starter ON: ON |
- |
| Inv-T (MG1) aftr IG-ON | Generator inverter temperature soon after power switch on (IG)/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
- | - |
| Inv-T (MG2) aftr IG-ON | Motor inverter temperature soon after power switch on (IG)/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
- | - |
| Mtr-T (MG2) aftr IG-ON | Motor (MG2) temperature soon after power switch on (IG)/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- | - |
| Conv-Tmp after IG-ON | Boost converter temperature soon after power switch on (IG)/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
- | - |
| SOC after IG-ON | HV battery state of charge soon after power switch on (IG)/ Min.: 0.0%, Max.: 100.0% |
- | - |
| Inv-Temp (MG1) Max | Maximum generator inverter temperature after power switch turned on (IG) in current trip/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
- | - |
| Inv-Temp (MG2) Max | Maximum motor inverter temperature after power switch turned on (IG) in current trip/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
- | - |
| Mtr-Temp (MG2) Max | Maximum motor (MG2) temperature after power switch turned on (IG) in current trip/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- | - |
| Converter Temp Max | Maximum converter temperature after power switch turned on (IG) in current trip/ Min.: 15°C(59°F), Max.: 150°C (302°F) |
- | - |
| Status of Charge Max | Maximum SOC after power switch turned on (IG) in current trip/ Min.: 0.0%, Max.: 100.0% |
- | - |
| Status of Charge Min | Minimum SOC after power switch turned on (IG) in current trip/ Min.: 0.0%, Max.: 100.0% |
- | - |
| Stop Light Switch | Stop light switch assembly condition/ ON or OFF |
Brake pedal depressed: ON |
- |
| Auxiliary Batt Temperature | Auxiliary battery temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Auxiliary battery temperature is 20°C (68°F): 20°C (68°F) |
- |
| Collision Signal (Airbag) | Airbag sensor assembly collision detection/ ON or OFF |
Collision detection by the airbag sensor assembly: ON |
- |
| TC Terminal | TC terminal state/ ON or OFF |
TC terminal connected: ON |
- |
| Inter Lock Switch | Interlock switch condition/ ON or OFF |
Power switch on (IG), connector cover assembly, UPR inverter cover, engine wire No. 4 (air conditioner wire) and service plug grip installed detached: ON |
- |
| EV Switch | EV drive mode switch (pattern select switch assembly) condition/ ON or OFF |
EV drive mode switch (pattern select switch assembly) being pushed and held: ON |
- |
| Back Up Lamp Relay | Back up light switch condition/ ON or OFF |
Shift lever in R ON |
- |
| ECO Mode | ECO mode transition availability/ ON or OFF |
In ECO mode: ON |
|
| Generate Torque | Generated drive torque/ Min.: -4096.0 Nm, Max.: 4095.8 Nm |
- | - |
| Prohibit Charge for P Pos | HV battery charge in shift lever in P prohibition state/ ON or OFF |
HV battery charge in shift lever in P prohibition: ON |
- |
| DC/DC Cnv Temp (Upper) | Boost converter temperature (upper)/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Safing Signal (Airbag) | Safing state of the airbag sensor assembly/ ON or OFF |
When safing state of the airbag sensor assembly: ON |
- |
| DC/DC Cnv Temp (Lower) | Boost converter temperature (lower)/ Min.: 15°C (59°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Normal Signal for A/B ECU | Control state of airbag sensor assembly/ ON or OFF |
When the airbag sensor assembly is operating normally: ON |
- |
| Mtr-T (MG1) aftr IG-ON | Generator (MG1) temperature soon after power switch on (IG)/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- | - |
| Mtr-Temp (MG1) Max | Maximum generator (MG1) temperature after power switch turned on (IG) in current trip/ Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- | - |
| Overvoltage Input to Conv | Overvoltage detection into boost converter/ ON or OFF |
Overvoltage is received by the boost converter: ON Normal: OFF |
- |
| Overvoltage Input to Inv | Overvoltage detection into inverter/ ON or OFF |
Overvoltage is received by the inverter: ON Normal: OFF |
- |
| Emergency Shutdown | Inverter emergency shutdown/ ON or OFF |
Inverter emergency shutdown: ON Normal: OFF |
- |
| MG1 Inverter Shutdown | Generator inverter shutdown/ ON or OFF |
Generator inverter shutdown: ON Normal: OFF |
- |
| MG1 Inverter Fail | Generator inverter stopped/ ON or OFF |
Generator inverter faulty: ON Normal: OFF |
- |
| MG2 Inverter Shutdown | Motor inverter shutdown/ ON or OFF |
Motor inverter shutdown: ON Normal: OFF |
- |
| MG2 Inverter Fail | Motor inverter stopped/ ON or OFF |
Motor inverter faulty: ON Normal: OFF |
- |
| Conv Shutdown | Boost converter shutdown/ ON or OFF |
Boost converter shutdown: ON Normal: OFF |
- |
| Converter Fail | Boost converter stopped/ ON or OFF |
Boost converter faulty: ON Normal: OFF |
- |
| Internal Shift Position | ECU internal shift condition/ P/R/N/D/B |
Matches currently selected shift position: P, R, N, D or B |
- |
| HV Start Condition | Indicates the hybrid start condition/ Norml / Pr A/C / Remote |
- | - |
| (Inverter) W/P Run Control Duty | Inverter water pump motor driver request duty/ Min.: 0.00%, Max.: 100.00% |
Power switch on (READY): 62.50 to 93.75% |
Power management control ECU |
| Engine Stop Request | Engine stop request/ Request or No |
Requesting engine stop: Request |
|
| Engine Idling Request | Engine idling request/ Request or No |
Requesting idle: Request |
|
| Main Batt Charging Rqst | Engine idling request to charge HV battery/ Request or No |
Requesting HV battery charging: Request |
|
| Aircon Request | Engine idling request from air conditioning amplifier assembly/ Request or No |
While an engine start is requested from the air conditioning amplifier assembly: Request |
air conditioning amplifier assembly |
| Engine Warming Up Rqst | Engine idling request to warm up engine/ Request or No |
While an engine warm-up is requested: Request After the engine is warmed up: No |
|
| SMRP Status | Operating state of SMRP (primary circuit monitor) ON or OFF |
Immediately after the power switch on (ST-ON) state occurred: ON After the above timing: OFF |
Cannot be confirmed using the Techstream. Use an oscilloscope.
|
| SMRB Status | Operating state of SMRB (primary circuit monitor) ON or OFF |
Power switch on (READY): ON |
|
| SMRG Status | Operating state of SMRG (primary circuit monitor) ON or OFF |
Power switch on (READY): ON |
|
| SMRP Control Status | Commanded state of SMRP/ ON or OFF |
Immediately after the power switch on (ST-ON) state occurred: ON After the above timing: OFF |
Cannot be confirmed using the Techstream. Use an oscilloscope. |
| SMRB Control Status | Commanded state of SMRB/ ON or OFF |
Power switch on (READY): ON |
- |
| SMRG Control Status | Commanded state of SMRG/ ON or OFF |
Power switch on (READY): ON |
- |
| MG1 Gate Status | Generator (MG1) gate status/ ON or OFF |
Shutting down generator inverter: ON Normal: OFF |
|
| MG2 Gate Status | Motor (MG2) gate status/ ON or OFF |
Shutting down motor inverter: ON Normal: OFF |
|
| Converter Gate Status | Boost converter gate status/ ON or OFF |
Shutting down boost converter: ON Normal: OFF |
|
| Aircon Gate Status | While A/C inverter is being shut off/ ON or OFF |
While A/C inverter is being shut off: ON Normal: OFF |
|
| Converter Carrier Freq | Boost converter signal carrier frequency/ 9.55kHz/9.13kHz/8.71kHz/8.29kHz/7.87kHz/7.45kHz/4.8kHz |
- | - |
| Delta SOC | Difference between maximum and minimum values of SOC/ Min.: 0.0%, Max.: 100.0% |
READY indicator on, engine stopped and no electrical load: 0.0 to 60.0% |
- |
| Batt Pack Current Val | HV battery current
Min.: -327.68 A, Max.: 327.67 A |
Immediately after a full-load acceleration with the engine stopped: Maximum 190.00 A Immediately after engine start with shift lever in P: 100.00 A or more |
HV battery current sensor circuit |
| Inhaling Air Temp | HV battery intake air temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) |
- | - |
| Auxiliary Battery Vol | Auxiliary battery voltage (Battery smart unit power source voltage) Min.: -40.00 V, Max.: 39.99 V |
11.00 to 15.00 V |
|
| Charge Control Value | Charge control wattage sent from battery smart unit to power management control ECU/ Min.: -64.0 kW, Max.: 63.5 kW |
-33.0 kW or more | - |
| Discharge Control Value | Discharge control wattage sent from battery smart unit to power management control ECU/ Min.: -64.0 kW, Max.: 63.5 kW |
30.0 kW or less | - |
| Cooling Fan Mode1 | Battery cooling blower assembly operation mode/ Min.: 0, Max.: 6 |
Power switch on (IG) or on (READY), and battery cooling blower assembly stopped: 0 Power switch on (IG) or on (READY), and battery cooling blower assembly low speed to high speed: 1→6 |
Battery cooling fan circuit |
| Cooling Fan Frequency 1 | Battery cooling blower assembly frequency Min.: 0.0 Hz, Max.: 6553.5 Hz |
Proportional to battery cooling blower assembly speed | Battery cooling fan circuit |
| ECU Control Mode | HV battery control mode/ Min.: 0, Max.: 4 |
Driving control mode: 0 Current sensor offset mode: 1 External charge control mode: 2 Power supply end mode: 3 |
- |
| Standby Blower Request | Battery cooling blower assembly Lo speed requested/ ON or OFF |
Constant: ON or OFF |
Air conditioning system |
| Temp of Batt TB1 | Battery module temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) |
Undisturbed for 1 day: Same as ambient air temperature |
|
| Temp of Batt TB2 | Battery module temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) |
Undisturbed for 1 day: Same as ambient air temperature |
|
| Temp of Batt TB3 | Battery module temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) |
Undisturbed for 1 day: Same as ambient air temperature |
|
| Battery Block Num | The number of battery blocks | Always: 17 | HV battery |
| Batt Block Minimum Vol | Battery block minimum voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 55.0 to 60.0%: 12.00 V or more |
- |
| Minimum Batt Block No | Battery block number with minimum voltage/ Min.: 0, Max.: 17 |
Any of block number 0 to 17 | - |
| Batt Block Max Vol | Battery block maximum voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 55.0 to 60.0%: 23.00 V or less |
- |
| Max Battery Block No | Battery block number with maximum voltage/ Min.: 0, Max.: 17 |
Any of block number 0 to 17 | - |
| Battery Block Vol -V01 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V02 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V03 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V04 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V05 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V06 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V07 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V08 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V09 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V10 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V11 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V12 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V13 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V14 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V15 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V16 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V17 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V |
SOC 60% : 12.00 to 20.00 V |
|
| Internal Resistance R01 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R02 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R03 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R04 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R05 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R06 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R07 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R08 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R09 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R10 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R11 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Internal Resistance R12 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω |
Always: 0.010 to 0.100 Ω |
HV battery |
| Battery Low Time | Number of times any battery block voltage dropped excessively/ Min.: 0, Max.: 65535 |
- | - |
| DC Inhibit Time | Number of times SOC of HV battery dropped excessively and discharge was prohibited/ Min.: 0, Max.: 65535 |
- | - |
| Battery too High Time | Number of times SOC of HV battery was high and charging was prohibited/ Min.: 0, Max.: 65535 |
- | - |
| Hot Temperature Time | Number of times HV battery temperature has become high/ Min.: 0, Max.: 65535 |
- | - |
ACTIVE TEST
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data list information can be displayed while performing Active Tests.
Note
It is necessary to use caution, because if the tester DLC connector becomes disconnected or if a communication error occurs during an Active Test, the vehicle could become inoperative (the READY indicator may go off).
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Hybrid Control / Active Test.
According to the display on the Techstream perform the appropriate Active Test.
| Tester Display | Test Part | Control Range | Test Details | Test Condition |
|---|---|---|---|---|
| Inspection Mode -2WD Inspection* | - | - | - | - |
| Inspection Mode -2WD Chassis-Dynamo* | - | - | - | - |
| Battery Charge | To charge the HV battery using the THS charger | - | Allows current to flow into the HV battery by operating the SMRS | Power switch on (IG), shift lever in P, other Active Tests not being performed, and auxiliary battery voltage is more than 9.5 V or more |
| Compression Test | To crank the engine continuously in order to measure the compression | ON / OFF | Allows the engine to continue cranking by activating generator (MG1) continuously | Power switch on (IG), HV system normal, not in cranking mode, and other Active Tests not being done |
| Activate the (Inverter) Water Pump |
|
ON / OFF | Activates the inverter water pump assembly continuously | Power switch on (IG) |
| Driving the Battery Cooling Fan |
|
1 to 6 | Stops the cooling fan or changes air volume mode | - |
| Connect the TC and TE1 | Batch display of warnings on combination meter | ON / OFF | TC terminal can be switched ON/OFF | Power switch on (IG), system is normal |
Note
*: Enter inspection mode Click here.