| DTC Code | DTC Name |
|---|---|
| P0A1A-200 | Generator Control Module |
| P0A1A-792 | Generator Control Module |
| P0A1A-793 | Generator Control Module |
DESCRIPTION
The MG ECU located in the inverter with converter assembly monitors its internal operation and detects the following malfunctions.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A1A | 200 | Generator resolver angle malfunction: The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit. (1 trip detection logic) |
|
| 792 | Resolver REF signal cycle malfunction: Excitation signal (REF signal) for resolver angle detection cycle malfunction. (1 trip detection logic) |
||
| 793 | Resolver REF signal oscillation stop malfunction: An error is detected when the excitation signal (REF signal) for resolver angle detection is not detected. (1 trip detection logic) |
| DTC No. | Data List |
|---|---|
| P0A1A-200 | Generator (MG1) Rev |
| P0A1A-792 | |
| P0A1A-793 |
MONITOR DESCRIPTION
The MG ECU performs many diagnostic tests to verify proper operation of internal ECU systems. In this diagnostic monitor, the MG ECU checks for an R/D (Resolver/Digital Converter) malfunction involving the generator resolver. If MG ECU detects an R/D error, it will conclude that there is an internal malfunction involving the generator resolver. The power management control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
| Related DTCs | P0A1A (INF 200): R/D converter resolver angle abnormality P0A1A (INF 792): REF malfunction (frequency abnormality) P0A1A (INF 793): REF malfunction (REF signal abnormality) |
| Required sensors / components | Inverter with converter assembly (MG ECU) |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
| TMC's intellectual property | - |
COMPONENT OPERATING RANGE
| Power management control ECU | DTC P0A1A (INF 200/792/793) is not detected |
CONFIRMATION DRIVING PATTERN
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY) with the shift lever in P, and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
Keep the engine running for 5 seconds or more.
Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more. [A]
Drive the vehicle backward the shift lever in R for 5 m (16 ft.) or more. [B]
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
Read the current DTCs.
Tech Tips
If a current DTC is output, the system is malfunctioning.
If current DTCs are not output, check for permanent DTCs.
Check that the permanent DTCs are cleared.
If the permanent DTCs are not cleared, perform the universal trip, and then check for permanent DTCs again.
WIRING DIAGRAM
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 5 seconds or more.*
Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
Keep the engine running for 5 seconds or more.
Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.
Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.
*: Lightly wiggle the connectors and wire harnesses up and down and right and left.
Note
If excessive pressure is applied while the connectors and wire harnesses are wiggled, they may be damaged. After the inspection, make sure to return the wire harnesses and clamps to their original position.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the E1 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the E1 inverter with converter assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK GENERATOR RESOLVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the E1 inverter with converter assembly connector.
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the E1 inverter with converter assembly connector.
| NG |
|
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the E1 inverter with converter assembly connector .
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the E1 inverter with converter assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK MOTOR RESOLVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the E1 inverter with converter assembly connector.
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the E1 inverter with converter assembly connector.
| NG |
|
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the E1inverter with converter assembly connector.
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Disconnect the E13 generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Reconnect the E13 generator resolver connector.
Reconnect the E1 inverter with converter assembly connector.
| B |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (When Using the Engine Support Bridge) Click here |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (When Not Using the Engine Support Bridge) Click here
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the E1 inverter with converter assembly connector.
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Disconnect the E12 motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Reconnect the E12 motor resolver connector.
Reconnect the E1 inverter with converter assembly connector.
| B |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (When Using the Engine Support Bridge) Click here |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (When Not Using the Engine Support Bridge) Click here