INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Automatic Air Conditioning System)
Disconnect the I61*1 or I184*2 automatic light control sensor connector.
*1: 10 Speaker
*2: 6 Speaker
Measure the voltage and resistance according to the value(s) in the table below.
| Standard Voltage | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
*1: 10 Speaker
*2: 6 Speaker
| *A | 10 Speaker |
| *B | 6 Speaker |
| *a | Front view of wire harness connector (to Automatic Light Control Sensor) |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the I61*1 or I184*2 automatic light control sensor connector.
*1: 10 Speaker
*2: 6 Speaker
Connect an oscilloscope to the automatic light control sensor connector.
| *A | 10 Speaker |
| *B | 6 Speaker |
| *a | Component with harness connected (Automatic Light Control Sensor) |
Check the waveform.
| OK | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
*1: 10 Speaker
*2: 6 Speaker
Tech Tips
If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, the automatic light control sensor may be malfunctioning.
INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Manual Air Conditioning System)
Disconnect the I185 automatic light control sensor connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to Automatic Light Control Sensor) |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the I185 automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
| *a | Component with harness connected (Automatic Light Control Sensor) |
Check the waveform.
| OK | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, the automatic light control sensor may be malfunctioning.