Note
When removing the cooler expansion valve by itself, be sure to install a new cooler expansion valve and new bolt for suction hose sub-assembly.
RECOVER REFRIGERANT FROM AIR CONDITIONING SYSTEM
Turn the A/C switch on.
Operate the air conditioning with a set temperature of 25°C (77°F) and the blower at low for 10 minutes to circulate the refrigerant. This causes most of the compressor oil from the various components of the air conditioning system to collect in the air conditioning compressor.
Turn the ignition switch off.
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
REMOVE WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY
REMOVE FRONT OUTER COWL TOP PANEL SUB-ASSEMBLY
Disengage the 2 clamps and separate the wire harness from the front outer cowl top panel sub-assembly.
Remove the 10 bolts and front outer cowl top panel sub-assembly.
DISCONNECT SUCTION HOSE SUB-ASSEMBLY (for TMMK Made)
Remove the bolt and rotate the hook connector.
Disconnect the suction hose sub-assembly.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent the entry of moisture and foreign matter.
DISCONNECT SUCTION PIPE SUB-ASSEMBLY (for SIA Made)
Remove the bolt and rotate the hook connector.
Disconnect the suction pipe sub-assembly.
Remove the O-ring from the suction pipe sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent the entry of moisture and foreign matter.
DISCONNECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
Disconnect the air conditioner tube and accessory assembly.
Remove the O-ring from the air conditioner tube and accessory assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent the entry of moisture and foreign matter.
REMOVE COOLER EXPANSION VALVE
Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.
| *a | Bolt for Suction Hose Sub-assembly |
Temporarily install the bolt for the suction hose sub-assembly halfway to the cooler expansion valve.
Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.
| *1 | No. 1 cooler evaporator sub-assembly |
Remove the 2 O-rings from the No. 1 cooler evaporator sub-assembly.