AIR CONDITIONING SYSTEM (for Manual Air Conditioning System), Diagnostic DTC:B1451

DTC Code DTC Name
B1451 Compressor Solenoid Circuit

DESCRIPTION

In this circuit, the compressor assembly with pulley (compressor solenoid) receives a refrigerant compression demand signal from the air conditioning amplifier assembly.

Based on this signal, the compressor assembly with pulley (compressor solenoid) changes the amount of compressor output.

DTC No. DTC Detection Condition Trouble Area
B1451 Open or short in compressor solenoid circuit
  • Compressor assembly with pulley (compressor solenoid)

  • Harness or connector between air conditioning amplifier assembly and compressor assembly with pulley (compressor solenoid)

  • Air conditioning amplifier assembly

WIRING DIAGRAM

A01HZ2ZE33

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID)


    1. A01HYUEE02
      Text in Illustration
      *a

      Component without harness connected

      (Compressor Assembly with Pulley (Compressor Solenoid))

      Disconnect the E74 compressor assembly with pulley (compressor solenoid) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E74-2 (SOL+) - E74-1 (SOL-) 20°C (68°F) 10 to 11 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID) - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E74-1 (SOL-) - Body ground Always Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID) - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. Disconnect the I77 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I77-2 (SOL+) - E74-2 (SOL+) Always Below 1 Ω
      I77-2 (SOL+) - Body ground Always 10 kΩ or higher
      Result
      Result Proceed to
      NG A
      OK (When troubleshooting according to Problem Symptoms Table) B
      OK (When troubleshooting according to the DTC) C

    B
    C
    A