AIR CONDITIONING AMPLIFIER ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| I77-1 (IG+) - I77-14 (GND) | B - W-B | Power source (IG) | Ignition switch ON | 11 to 14 V |
| I77-1 (IG+) - I77-14 (GND) | B - W-B | Power source (IG) | Ignition switch off | Below 1 V |
| I77-2 (SOL+) - I77-14 (GND) | W - W-B | Compressor solenoid operation signal | Engine running A/C switch: on Blower switch: LO |
Pulse generation (See waveform 1) |
| I77-5 (TAM) - I77-13 (SG-2) | P - GR | Ambient temperature sensor signal | Ignition switch ON Ambient temperature: 25°C (77°F) |
1.35 to 1.75 V |
| I77-5 (TAM) - I77-13 (SG-2) | P - GR | Ambient temperature sensor signal | Ignition switch ON Ambient temperature: 40°C (104°F) |
0.9 to 1.2 V |
| I77-7 (FLOQ) - I77-13 (SG-2) | G - GR | A/C flow sensor signal | Ignition switch ON A/C switch: off |
3.8 to 4.2 V |
| I77-7 (FLOQ) - I77-13 (SG-2) | G - GR | A/C flow sensor signal | Ignition switch ON A/C switch: on Blower switch: HI |
0.7 to 3.8 V |
| I77-9 (PRE) - I77-13 (SG-2) | R - GR | Air conditioning pressure sensor signal | Engine running A/C system operating Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.8 kgf/cm2, 439 psi)) |
4.80 V or higher |
| I77-9 (PRE) - I77-13 (SG-2) | R - GR | Air conditioning pressure sensor signal | Engine running A/C system operating Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 26 psi)) |
Below 0.50 V |
| I77-9 (PRE) - I77-13 (SG-2) | R - GR | Air conditioning pressure sensor signal | Engine running A/C system operating Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) |
0.50 to 4.80 V |
| I77-10 (S5-3) - I77-13 (SG-2) | V - GR | Power supply for air conditioning pressure sensor | Ignition switch ON A/C switch: on |
4.75 to 5.25 V |
| I77-10 (S5-3) - I77-13 (SG-2) | V - GR | Power supply for air conditioning pressure sensor | Ignition switch ON A/C switch: off |
Below 1 V |
| I77-11 (CANH) - I77-12 (CANL) | V - W | CAN communication system | CAN communication circuit | Pulse generation |
| I77-13 (SG-2) - Body ground | GR - Body ground | Ground for air conditioning pressure sensor, ambient temperature sensor | Always | Below 1 V |
| I77-14 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| I77-21 (B) - I77-14 (GND) | Y - W-B | Power source (Back-up) | Always | 11 to 14 V |
| I77-22 (BLW) - I77-14 (GND) | R - W-B | Blower motor speed control signal | Ignition switch ON Blower switch: LO |
Pulse generation (See waveform 2) |
| I77-30 (S5-1) - I77-13 (SG-2) | B - GR | Power supply for A/C flow sensor | Ignition switch off | Below 1 V |
| I77-30 (S5-1) - I77-13 (SG-2) | B - GR | Power supply for A/C flow sensor | Ignition switch ON | 4.5 to 5.5 V |
| I77-37 (LIN1) - I77-14 (GND) | V - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
| z1-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 V |
| z1-3 (BUS) - z1-2 (BUS G) | - | BUS IC control signal | Ignition switch ON | Pulse generation |
| z1-4 (B BUS) - z1-2 (BUS G) | - | Power supply for BUS IC | Always | 11 to 14 V |
| z1-5 (SGA) - Body ground | - | Ground for evaporator temperature sensor | Always | Below 1 V |
| z1-6 (TEA) - z1-5 (SGA) | - | Evaporator temperature sensor signal | Ignition switch ON Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
| z1-6 (TEA) - z1-5 (SGA) | - | Evaporator temperature sensor signal | Ignition switch ON Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | I77-2 (SOL+) - I77-14 (GND) |
| Tool Setting | 5 V/DIV., 500 μs/DIV. |
| Vehicle Condition | Engine running A/C switch: on Blower switch: LO |
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | I77-22 (BLW) - I77-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Vehicle Condition | Ignition switch ON Blower switch: LO |
AIR CONDITIONING CONTROL ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| I56-2 (IG+) - I56-6 (GND) | R - W-B | Power source (IG) | Ignition switch off | Below 1 V |
| I56-2 (IG+) - I56-6 (GND) | R - W-B | Power source (IG) | Ignition switch ON | 11 to 14 V |
| I56-6 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
| I56-9 (LIN1) - Body ground | V - Body ground | LIN communication signal | Ignition switch ON | Pulse generation |
| I56-11 (ILL+) - Body ground | G - Body ground | Illumination signal | Light control switch off | Below 1 V |
| I56-11 (ILL+) - Body ground | G - Body ground | Illumination signal | Light control switch tail or head position | 11 to 14 V |
| I56-15 (ILL-) - Body ground | SB - Body ground | Illumination signal | Light control switch off | Below 1 V |
| I56-15 (ILL-) - Body ground | SB - Body ground | Illumination signal | Light control switch tail or head position | Pulse generation |